Digital
Overhead Stirrer
User Manual
OS40-Pro
LCD Digital Enhanced Overhead Stirrer
OS40-S
LED Digital Enhanced Overhead Stirrer
(Le Laborantin - réf.702323)
OS20-Pro
LCD Digital Overhead Stirrer
OS20-S
LED Digital Overhead Stirrer
(Le Laborantin - réf.701574)
Please read the User Manual carefully before use, and follow all
operating and safety instructions!
Technical specifications and outline are subject to change without prior
notice.

Other manuals for DLab OS20-Pro

Questions and Answers

  • R
    Rebecca KochAug 9, 2025
    What to do if my DLab OS20-Pro doesn’t stir?
    • C
      cindy31Aug 9, 2025
      If your DLab Laboratory Equipment isn't stirring, first ensure you've set a target speed by rotating the speed control knob and pressing it to start. Also, verify that all cable connections are firmly plugged in. If the issue persists, the belt might be broken, requiring replacement. Alternatively, the driven board or photosensor could be faulty and need replacing.
  • J
    Jennifer BoydAug 18, 2025
    How to troubleshoot a DLab OS20-Pro with no operation response (LED off)?
    • J
      Jonathan MclaughlinAug 18, 2025
      If your DLab Laboratory Equipment shows no operation response and the LED is off, start by checking and connecting the power supply, then power it on again. Ensure that the power switch is turned on. If the problem continues, open the instrument and check all cable connections, reconnecting them as needed.
  • S
    stephaniewilliamsAug 27, 2025
    Why is the speed control inaccurate on my DLab Laboratory Equipment?
    • J
      Jessica WilliamsAug 27, 2025
      If the speed control on your DLab Laboratory Equipment isn't accurate, the drill chuck might be faulty and require replacement. Alternatively, the photosensor could be failing and need replacing.

Summary

Preface

Service and Support

Product Warranty Information

Safety Instructions

General Safety Precautions

Essential safety guidelines for operating the overhead stirrer, including proper grounding, personal protective equipment, and safe environment setup.

Proper Use Guidelines

Inspection and Item Listing

Receiving Inspection

Procedure for unpacking and checking the instrument for transport damage before connecting to power.

Listing of Items

Details the standard components included with the instrument, such as the main unit, power cable, and user manual.

System Assembly Guide

Install Stand

Instructions for assembling the stand and attaching the main unit securely to ensure stability and safety.

Install Stirring Impeller

Guide on plugging in and adjusting the depth of the stirring impeller into the vessel using the drill chuck.

Trial Running Procedure

Instrument Function Overview

Control Panel Layout

Visual identification and labeling of the main operational components for both LCD and LED digital overhead stirrers.

Display Operation and Indicators

Overload Protection

Interface and Output (LCD Digital)

Troubleshooting Faults

Maintenance and Cleaning

Associated Standards and Regulations

Technical Specifications

Ordering Information and Accessories