8860 Installation and Programming Guide | Digital Monitoring Products 6
PROGRAM THE KEYPAD
To access the Keypad Installer Options menu, press Options in the Carousel menu. Tap the Installer Options wrench icon,
enter 3577 (INST), then press CMD.
Installer Options
To program keypad options, press the Installer Options wrench icon and enter 3577
(INST). Press CMD. Select an option to configure its settings. Press the back arrow to
back out of the menu.
Set Panic Buttons
Use this option to enable or disable the panic keys. Select the panic buttons you would
like to have displayed on the keypad. Once the panic option is enabled, a check mark
displays next to the selected options.
Set Keypad Address
Set the current keypad address to be the same as the panel device number. The default
address is set at 01. To change the current address, press any select area to clear the
keypad display, enter the new address, and press CMD. It’s not necessary to enter a
leading zero for addresses 1 to 9.
Set Default Keypad Message
Enter a custom message of up to sixteen characters to appear at the top of the keypad
display. Press any select area, enter a new message, and press CMD. If a message has
been entered, it will display in the field until changed.
Check for Updates
The keypad has local and remote update capabilities. The keypad must be connected to
Wi-Fi to perform a local and remote update. The remote update capabilities can be used
for per device updates through Dealer Admin™.