TIME CHANGES
Choose YES to allow the communicator to request automatic time changes from the
SCS‑1R or SCS‑VR receiver. The receiver must be programmed to send and receive time
change updates from the host computer at least every 24 hours. Choose NO to disable
automatic time change requests. The default is YES.
HOURS FROM GMT
When time zone is programmed YES, enter the number (0‑23) that indicates the
Greenwich Mean Time zone (GMT) where the communicator is located. The default is 6.
See Table 6 for GMT values.
GMT CITY/TIME ZONE GMT CITY/TIME ZONE
0 London, Monrovia, Lisbon 12 Fiji, Marshall Island, Wellington
1 Cape Verde Island, Azores 13 New Cadelonia
2 Mid‑Atlantic 14 Guam, Sydney
3 Buenos Aires, Georgetown 15 Tokyo, Seoul
4 Atlantic Time (Canada), Caracas 16 Hong Kong, Singapore
5 Eastern Time (US, Canada) Bogota 17 Bangkok, Hanoi
6 Central Time (US, Canada) Saskatchewan 18 Dhaka, Almaty
7 Mountain Time (US, Canada), Edmonton 19 Islamabad, Karachi
8 Pacific Time (US, Canada), Tijuana 20 Abu Dhabi, Kazan
9 Alaska 21 Moscow, Bagdad
10 Hawaii 22 Eastern Europe
11 Midway Island, Samoa 23 Rome, Paris, Berlin
KEYPAD INPUT
Select NONE to allow zone4 to function as normally programmed. The default is NONE.
Select ECP to enable communication between the communicator and an Ademco/
Honeywell panel using the +Z4‑ terminals. Using the Ademco/Honeywell ECP Bus, the
communicator can add, delete, and change user codes as well as arm and disarm the
Ademco/Honeywell panel. The communicator will forward alarm messages from the
Ademco/Honeywell panel to the central station.
Select DSC to enable communication between the communicator and a DSC PowerSeries
panel using the Z4‑ terminal. Using the DSC bus, the communicator can add, delete,
and change user codes as well as arm and disarm the DSC panel. The communicator will
forward alarm messages from the DSC panel to the central station.
See Ademco/Honeywell ECP Connection for examples of panel wiring and necessary
Ademco/Honeywell panel programming.
CID FORMAT
Select DMP to send CID messages as Serial 3 format. Select CID to send messages as DMP
string with raw CID message appended. Refer to Figure 16. Default is DMP.
This feature requires SCS‑VR Version 1.4.6 and higher or SCS‑150 Version 107 and higher.
TIME CHG NO YES
HRS FROM GMT: 6
Table 6: GMT Time Zones
KYPD INPUT
NONE ECP DSC
CID FORMAT
DMP CID
9910 3155 c 5550 18 1 110 00 010 2
The receiver sending
the message
The account number
of the DMP panel
CID Identifier
The account number
of the host panel
The message type
that identifies
the message as CID
The new event
The event code
for a Zone Fire Alarm
Partition
Number
Zone
Number
Checksum
DMP String CID String
Figure 16: CID Format Option