ARMING AND DISARMING
Use the Virtual Keypad App
Using a smartphone with the DMP Virtual Keypad App or a computer with VirtualKeypad.com, you can connect to the
communicator to arm areas, turn outputs on and off, and add, edit, or remove users. See Figure 10.
Use Outputs
A burglary control panel zone may be programmed as an arming zone and connected to output O1 or O2. See
Figure 11. Program the output number in armed output or remote arming output in output options when programming
the communicator. See Armed Output or Remote Arming Output. The communicator output connections can be used
with any of the applications listed in this guide. See Applications.
Communicator to Panel Burglary Zones
1. Connect the communicators Z1 (zone 1) terminal to the control panel’s armed output terminal.
2. Connect the communicators O1 (output 1) terminal to the control panel’s keyswitch or arming zone.
Figure 10: Virtual Keypad Applications
Figure 11: Communicator to Burglary Control Panel Zones
+DC- Z1
Z2 Z3
G
T
R
+Z4-
O1 O2
+
Use 18-22 AWG
for Power Supply
connection
O2
12 VDC Aux. Output
+
-
GND
Zone 1
Zone 2
Control Panel EOL resistor