User Manual of DOLCWIUHFP
8
Table 2.3.2-1
Description Position A Position B
Install Height Over 2.2 m (see the Left View of Position B in Figure 2.3.1-1)
Pole Position (H) Over 0.25 m horizontal far from the edge of the lane (See Over View of Side
Installation in Figure 2.3.1-1
Pole Position (V) 1.0 m far in vertical from the Gate 1.0 M far in vertical from the Ticket Box
Offset Angle with Lane
About 30
º About 60º
Offset Angle with Pole
About 0
º About 15º
2.3.3 Notice
1. If the DC Power is not waterproof, it is suggested to insert into the Ticket Box or be
covered.
2. The dia of the extension power core should be 1.5 mm" if the length is over 5.0 m.
3. The data wire should be with shielding layer and should be connected with the GND to
avoid any interference.
4. Adjust the reader range to make sure the tag can be detected when the vehicle with the tag
is approaching ticket box and within one lane area only, so that there is only one vehicle and one
tag in the operation area to avoid any wrong operation.
2.4 Overhead Installation
2.4.1 Overview
Take a simple parking lot for example; the width of the lane is 3.5 M, while the distance
between Gate and Ticket Box is 5 M. The reader is expected to be placed to allow time for the
gate to open so the car can roll through without stopping while not allowing room for an untagged
car to be between the car being read and the gate. For the details please refer to the Figure 2.4.1-1