EasyManuals Logo

Dometic FreshWell 3000 User Manual

Dometic FreshWell 3000
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
EN
Technical description FreshWell3000
16
6.4 Air conditioning modes
The under-bench air conditioner has the following air conditioning modes:
Air conditioning
mode
Display
message
Explanation
Automatic In this mode the air conditioner sets the temperature
(set point) automatically and manages the compressor,
heat pump and fan speed by comparing the set point
with the room temperature and it sets the
corresponding conditioning mode (see following
table).
The , + and buttons are deactivated in this mode.
Cooling You specify the temperature and blower settings, and
the air conditioner cools the interior to this tempera-
ture.
Heating You specify the temperature and blower settings, and
the air conditioner heats the interior to this tempera-
ture.
Circulating air You specify the blower level, and the air conditioner
blows air into the interior
.
Dehumidification You specify the temperature, and the air conditioner
cools the interior to this temperature and controls the
necessary blower output and dehumidifys the interior
(Circulating air mode).
The button is deactivated in this mode.
Current room
temperature ϑ
ϑ ≤ 20 °C 22 °C < ϑ < 25 °C ϑ 25 °C
Set point: 2C 2C 2C
Conditioning
mode:
Heating or
Circulating air
Dehumidification or
Circulating air
Cooling
FreshWell3000-O-16s.book Seite 16 Freitag, 18. August 2017 2:14 14

Table of Contents

Other manuals for Dometic FreshWell 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic FreshWell 3000 and is the answer not in the manual?

Dometic FreshWell 3000 Specifications

General IconGeneral
BrandDometic
ModelFreshWell 3000
CategoryAir Conditioner
LanguageEnglish

Related product manuals