EasyManuals Logo

Dometic RM2612 Service Tips

Dometic RM2612
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE
RM2612, RM2812, RM2652, RM2852 REFRIGERATORS
SYMPTOM
. .
CAUSE
REFRIGERATOR SECTION
1.
No operation
-
no panel lights
2.
No operation
-
has panel lights
3.
No AC operation
-
operates on gas mode
4.
No Gas operation
-
operates on AC mode
5.
Insufficient cooling on all modes.
6.
Insufficient cooling on AC
-
cools properly on
gas mode.
Operation
DC Volts
Fuse
Wiring
Upper Circuit Board
Lower Circuit Board
Operation
DC Volts
Thermistor
Fuses
Wiring
Lower Circuit Board
Operation
AC Volts
Fuse
Heating Element
Wiring
Lower Circuit Board
Operation
LP Gas
Manual Gas Valve
Igniter
High Voltage Cable
Electrode
Solenoid
Wiring
Lower Circuit Board
Ventilation
Leveling
Ambient Temperature
Air Leaks
Thermistor
Cooling Unit
AC Volts
Heating Element
Lower Circuit Board

Other manuals for Dometic RM2612

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM2612 and is the answer not in the manual?

Dometic RM2612 Specifications

General IconGeneral
BrandDometic
ModelRM2612
CategoryRefrigerator
LanguageEnglish

Related product manuals