THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE
RM2612, RM2812, RM2652, RM2852 REFRIGERATORS
SYMPTOM
. .
CAUSE
REFRIGERATOR SECTION
1.
No operation
-
no panel lights
2.
No operation
-
has panel lights
3.
No AC operation
-
operates on gas mode
4.
No Gas operation
-
operates on AC mode
5.
Insufficient cooling on all modes.
6.
Insufficient cooling on AC
-
cools properly on
gas mode.
Operation
DC Volts
Fuse
Wiring
Upper Circuit Board
Lower Circuit Board
Operation
DC Volts
Thermistor
Fuses
Wiring
Lower Circuit Board
Operation
AC Volts
Fuse
Heating Element
Wiring
Lower Circuit Board
Operation
LP Gas
Manual Gas Valve
Igniter
High Voltage Cable
Electrode
Solenoid
Wiring
Lower Circuit Board
Ventilation
Leveling
Ambient Temperature
Air Leaks
Thermistor
Cooling Unit
AC Volts
Heating Element
Lower Circuit Board