SECTION 7
LP GAS COMPONENTS
MANUAL GAS SHUTOFF VALVE
To check the shutoff valve, remove and inspect for any obstructions.
Gas
Connection
Manual Gas
Shutoff Valve
Shown in “ON”
position)
RM2652
&
RM2852
Gas Connection
\
n
fl
nl
Manual Gas Shutoff
Valve (Shown in “ON” Position)
Pressure
Test
Port
Orifice
ORIFICE
The orifice is cleaned by using an alcohol based solvent and allowing to air dry.
If there is a lack of cooling on gas operation, verify the orifice is the proper size per the chart below:
RM2612
#53
RM2812
#58
RM2652 #58
RM2852 #58