THERMOCOUPLE
. .
The thermocouple should produce 25 to 35 millivolts when connected to the lower circuit board. Any
reading below 18 millivolts could cause erratic gas operation.
BURNER
The burner should be cleaned periodically, at least once a year. Soak the burner in an alcohol-based
solvent and allow to air dry.
FLUE BAFFLE
At least once a year, clean and check for any damage.
The proper position of the baffle above the burner should be as follows:
RM2612 1-5/8"
RM2812
1-3/4"
RM2652 1-7/8"
RM2852
1-7/8"
FLUE TUBE
The flue tube must be cleaned periodically. Remove flue cap and flue baffle, then cover the burner and
clean by using a flue brush,
Dometic
Part No. 0151404001,
WIRING
EXTERNAL WIRING
A. 120 volts AC Connection
The refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazards
and should be plugged directly into a properly grounded three-prong receptacle.
B. 12 Volt DC Connection
The 12 volt DC supply circuit must be fused, and the maximum fuse size is 5 amps.
DO NOT
use the chassis or vehicle frame as one of the conductors,
Clean Direct Current (DC) power is mandatory for high-tech circuits to operate as designed.
A battery will provide straight line DC power.
The converter and alternator produces DC power by a series‘of diodes that rectify alternating
current to DC.
INTERNAL WIRING
Verify the refrigerator is wired per the wiring diagram for the
exact
model you are working on. See the
following typical wiring diagram.
14