SOLENOID VALVE
Check the solenoid coil with a properly calibrated ohm meter. Remove the connector from the solenoid
and measure the resistance across the terminals. The proper reading would be 49 ohms with tolerance
range of ten percent.
. .
Next, hook up a manometer at the test port. Then check for DC volts at gas valve terminals while the
unit is in trial-for-ianition. If DC volts are present and pressure is low, replace the valve. If DC volts are
not present at the valve while the unit is in trial-for-ianition, verify that the wire at Plug 3, Terminal 2 on
lower circuit board have DC volts (9 or more).
RM2612
&
RM2612
RM2652
& RM2652
IGNITER
First verify proper voltage at the positive (+) and ground (-) terminals of
the ignitor. The reading should be within one volt of incoming voltage at
the main terminal block during trial-for-ianition
Next, remove high voltage cable from igniter. The igniter should pro-
duce a sparking sound, during trial-for-ianition. If not, replace the
igniter.
The igniter installed on the refrigerators as original equipment is part
number 2931132019 (RV Gas Model 679). This igniter is rated 50 MA.
This igniter may also be used on any other model.
DO NOT install the Channel Mark 6, Model 12E igniter (shown below) as a service replacement part.
MARK 6, MODEL
12E
W/O 1282150 9318
12VDC
25mA
CHANNEL PRODUCTS
CHESTERLAND OH 44026
Installation of the Channel Products, Inc.,
Gasliter
Mark 6, Model
12E,
will VOID the Warranty on the