EasyManua.ls Logo

Dometic RM2612 - Door Position; Ambient Temperature; Cooling Unit

Dometic RM2612
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D. Replace the top
decoration panel.
Third: Two screws installed as shown in rear base.
DOOR POSITION
The door position can be checked by observing any misalignment of the door in relation to the frame.
Loosen the hinge bracket screws, reposition the door then tighten the hinge bracket screws.
To adjust up or down, add or remove washers from the lower hinge pin.
AMBIENT TEMPERATURE
As the ambient temperature increases, the air temperature in the area of the cooling unit increases.
The double door refrigerators should maintain approximately 43 degrees food storage tempera-
ture at 110 degree ambient temperature.
COOLING UNIT
The cooling unit is a self-contained, hermetically sealed set of coils where the refrigeration process
takes place. The chemicals involved in the cooling process include hydrogen, ammonia, water and a
rust inhibiting agent. There are no repairs recommended on the cooling unit.
18

Other manuals for Dometic RM2612

Related product manuals