D. Replace the top
decoration panel.
Third: Two screws installed as shown in rear base.
DOOR POSITION
The door position can be checked by observing any misalignment of the door in relation to the frame.
Loosen the hinge bracket screws, reposition the door then tighten the hinge bracket screws.
To adjust up or down, add or remove washers from the lower hinge pin.
AMBIENT TEMPERATURE
As the ambient temperature increases, the air temperature in the area of the cooling unit increases.
The double door refrigerators should maintain approximately 43 degrees food storage tempera-
ture at 110 degree ambient temperature.
COOLING UNIT
The cooling unit is a self-contained, hermetically sealed set of coils where the refrigeration process
takes place. The chemicals involved in the cooling process include hydrogen, ammonia, water and a
rust inhibiting agent. There are no repairs recommended on the cooling unit.