If 120 volts AC becomes available while the CHECK indicator lamp is on, the control system will switch to
120 volt AC operation, The CHECK lamp will not turn off until the main power ON/OFF button is pressed to
the OFF then ON position.
In AUTO mode operation, the temperature is controlled by a single temperature setting.
MANUAL MODE
When operating in the MANUAL mode, the AUTO mode indicator lamp (A) will be off, and the refrigerator
will run continuously on the energy source selected by the control system.
NOTE: The food in the lower compartment may be frozen if the refrigerator is left on “MANUAL” mode.
STANDBY MODE
. .
This control system contains a feature that will continue to operate the cooling system in the event of a failure
of a major operating component. If the control cannot read the temperature sensor and operate at the preset
temperature, then the control will run the cooling unit like the MANUAL mode.
The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed and the
system is reset.
AC VOLTAGE REQUIREMENTS
The proper operating range is 100 to 132 volts. If voltage drops below 100 volts, cooling efficiency will
decrease with voltage decrease. The refrigerator will not switch to another mode of operation until all
AC
power is lost.
The refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazards, and
should be plugged directly into a properly grounded three-prong receptacle.
12
Volt AC
120
Volt AC
Receptacle