DONPER USA—USER MANUAL
15 — COPYRIGHT DONPER USA 2015
OPERATING IN THE AUTO MODE:
There are two Auto buons on the front control panel, one for the le
barrel and one for the right cylinder. The two sides can be controlled in‐
dependently of each other. Press the Auto buon on the control panel
to begin freezing inside the corresponding freezing cylinder. When in
Auto Mode, the indicator light will turn on along with the corresponding
beater motor. The numeral values on the display will increase from 0 to
99 and then stop at 00. When the number value reaches 00, this indi‐
cates that the product in the freezing cylinder is ready to serve. When
the number reaches 00, the indicator light above the AUTO buon will
then flash, indicang that the product is ready and has reached the de‐
sired firmness level. Note that the hopper cooling switch should also be
turned on during the AUTO mode operaon to keep the product in the
hoppers refrigerated and to prevent spoiling. NEVER RUN THE MACHINE
IN AUTO MODE WITH WATER IN THE FREEZING CYLINDERS—DAMAGE
WILL OCCUR.
Adjusng the Product Firmness Level:
With the Power Switch ON and both Auto buons OFF, press the up and
down buons simultaneously and hold for 5 seconds (machine will beep
5 mes) for the side you wish to adjust. A numerical value of 1 to 10
(the firmness seng) will begin to flash on the screen. Use the up and
down buons to adjust the firmness seng with 1 being soer product
and 10 being firmer product. Once the firmness is set, the control panel
will automacally return back to “00” aer about 10 seconds of no fur‐
ther adjustments.