DONPER USA—USER MANUAL
5 — COPYRIGHT DONPER USA 2015
Electrical Requirements (BH7480)
Voltage 230 V 60 Hz Single Phase
Rated Input Power 22 A (4.6 kW)
Power Plug Type NEMA L6‐30P
Required Breaker Size 30A, Double Pole
Main Compressor 2 HP R404A
Hopper Cooling Compressor 1/6 HP R134A
Drive Motors (ea) 1 HP (750W)
Size and Capacity (BH7480)
Freezing Cylinders (ea) 2 Qt (1.9 L)
Refrigerated Hoppers (ea) 9.5 Qt ( 9 L)
Appx. Hourly Producon* 46‐59 Qt (44‐56 L)
Height 56.5 in (1435 mm)
Width 21.25 in (540 mm)
Depth 30.5 in (750 mm)
Weight 397 lbs (180 kg)
R404A (main compressor) 900 g
R134a (hopper compressor) 130g
A dedicated 30 amp circuit is required to operate the machine.
Using a shared circuit may damage the machine and will void the
machine warranty.
The machine uses an air cooled refrigeraon system which requires
a minimum of 6‐8 inches of clearance on the le and right sides of
the machine and at least 8 inches of clearance behind the machine.