28
1838-065 Issued 3-19
Version D
Program from System Keypad ONLY
These features ONLY need to be re-programmed when a NEW 1838 access controller is to be used with EXISTING OLDER 1830
telephone entry systems that have a smaller memory size (less than 3000) with or without cards and anti-pass back capability
and all units are being managed by DKS
Remote Account Manager Software with the “Share Info” feature. The new 1838 chip
specification MUST MATCH the older 1830 chip specifications or
EXISTING
programming conflicts will occur.
Factory setting = Step 2 - 8 (3000), Step 4 - 2 (Using Cards WITH Anti-Pass Back)
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will read: MEM SIZE? 1 THRU 8
2. Enter a single-digit for memory size (1-8), then press (beep).
1=25 2=75 3=125 4=250 5=500 6=1000 7=2000 8=3000
The OPTIONAL LCD display will read: xxxx MEM OK? 0=N 1=Y (xxxx is the memory you have chosen).
3. Press YES (beep), OR NO (beep).
Note: Selecting NO (0*) will go back to the previous step.
After YES (1*) is entered, The OPTIONAL LCD display will read: CARDS 0=N 1=Y 2=ANTI
4. Press (beep) NO Cards, OR (beep) Use Cards, OR (beep) Use Cards with Anti-Pass Back
The OPTIONAL LCD display will read: ERASE MEM? 1=Y 0=N
5. Press YES (beep), OR NO (beep).
Note: Selecting NO (0*) will go back to the first step.
After YES (1* BEEP) is entered, A long beep will be heard after memory has been erased (beeeeeep).
? ? ? ?
5
9
1
1
1
2
0
0
0
STOP!! If the 1838 is to be programmed from a PC, NO other programming is required at the 1838 itself. Refer to the
Remote Account Manager for Windows Software help screens for additional programming information. Continue with the
remaining sections in this chapter if the 1838 will be programmed by any other method. If the factory setting matches your
need, there is no reason to reprogram that section.
Remember that advanced features like relay hold open time zones,
security levels, and elevator control functions can ONLY be
programmed from the Remote Account Manager Software. If any of
these advanced features are being used, DO NOT proceed with any
other programming steps in this manual.
SOFT
WA
RE
IN
STALLE
D
SOFTWARE
INST
ALLED
PC’s only, NOT for use with MACs
SOFTWA
RE
INS
TA
LLED
CAUTION:
This programming
sequence will erase ALL
information stored on the
existing memory chip.
3.2.11 Re-Program Memory Size, with/without Cards and Anti-Pass Back
The following programming sequence turns the “LIVE Transaction viewing on your PC On or Off.
When turned ON, all transactions can be viewed “Real-Time” from your PC.
When turned OFF, the transaction buffer must be downloaded before viewing the transaction history log. The transaction buffer
stores the last 8000 events when downloaded.
Factory setting = 0 (OFF)
3.2.12 Turn LIVE Transaction Viewing On or Off
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will read: view live? 0=NO 1=YES
2. Enter for YES - view live transactions or for NO - don’t view live transactions, then press (beep).
3. Press together to end this programming sequence (beeeeeep).
? ? ? ?
9
1
1
0
0
Download REMOTE ACCOUNT MANAGER Software FREE at:
http://www.doorking.com/telephone/software