47
1838-065 Issued 3-19
Version D
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will show the 10-digit phone number or system ID number.
? ? ? ?
6
5
6.1.7 Display DKS Data over IP Phone Number or ID Number - Optional LCD
Display Must be Installed
This will allow you to see the DKS Data over IP issued 10-digit phone number or system ID number that has been programmed
into the 1838. OPTIONAL LCD display (P/N 1838-220) needed.
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will show one of the following and the 1838 will BEEP accordingly:
? ? ? ?
9
2
6.1.8 Test Connection to DKS Data over IP - Optional LCD Display MUST be Installed
This will allow you to test the connection to the DKS Data over IP or display problems that may have occurred. OPTIONAL LCD
display (P/N 1838-220) needed.
Note: The display will show C's (C C C C C C C C C C) if a phone number or ID has NOT been programmed.
6.1.9 Turn DKS Data over IP OFF or ON
1. Press and enter your four-digit MASTER CODE (beep).
2. Press (beep) to turn OFF, OR (beep) to turn ON.
3. Press together to end this programming sequence (beeeeeep).
? ? ? ?
5
5
0 1
0
Note: You can test the 1838 connection to DKS Data over IP and analyze problems that may occur
using section 6.1.8.
Note: If there is pending data to be transfered when this test is performed, the data transfer will occur.
Use the following sequence to turn DKS Data over IP OFF or ON.
If you are going to use the RS232 connection for any other RS232 functions other than DKS Data over IP (e.g., connecting a PC
directly to the entry system via the RS232 terminal), DKS Data over IP must be turned OFF.
The DKS Data over IP must be ON to use the system with DKS Data over IP. Note: When section 3.2.10 (DKS Data over IP
Phone Number or System ID Number) is programmed, DKS Data over IP is automatically turned ON.
If there is NOT a valid 10 digit system phone number or system ID number in memory, the system will emit three (3) short
beeps. Beep ... Beep ... Beep
System is Registered - (beep) one beep
- System is registered and communication to the DKS Data over IP is good.
Check Registration - (beep-beep) two beeps
- Make sure your registration is current and this system is set to DKS Data over IP on the
registration screen. Also, be sure that the system phone number or ID number and the
master code are set the same on the DKS Data over IP and the 1838.
Program 10 Digit ID - (beep-beep-beep) three beeps
- There is not a valid 10-digit ID in the system memory. (see section 3.2.10)
Turn DKS Data over IP On - (beep-beep-beep-beep) four beeps
- There is a valid 10-digit ID, but DKS Data over IP is turned OFF. (see section 6.1.9)
No DKS Data over IP Contact - (beep-beep-beep-beep-beep) five beeps
- Communication to DKS Data over IP could not be made.