2112-065-G-12-21
9
TB3 Terminal
Descriptions
5V OUT
GND
CALL
LED
GND
TALK
LED
GND
TB2
TB3
CARD 1
B
CARD 1
A
GND
+12VDC
OUT
GND
+ VDC
OUT
GND
RELAY 1
COM
RELAY 1
NC
RELAY 1
NO
POT 1
TB2
TB3
TB1
J1
2
1
4
3
J3 J8
+
POT 2
MIC OUT 1
BATTERY
POWER
KEYPAD
GND
BUTTON
Z
GND
TAMPER
SW
GND
BUTTON
A
GND
BUTTON
CALL
GND
POST
KEY SW
TB4
TB1
BATT +
GND
RELAY 3
COM
RELAY 3
RELAY 2
COM
RELAY 2
NC
RELAY 2
NO
N/C
16 VAC
IN
16 VAC
IN
+
8168-102
SOUND CARD
POWER
MUTE/REC
DISPLAY
CAMERA
ETHERNET
USB
USB
Raspberry Pi 3 Model B
SECTION 2 - WIRING
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Earth Ground
Relay 1 Com
Relay 1 NC
Relay 1 NO
BATT
PO
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
TB1TB3
TB2
NOT
USED
TB4
NOT
USED
Relay 2 Com
Relay 2 NC
Relay 2 NO
Not Used
16 VAC IN
16 VAC IN
Relay 3 Com
Relay 3 Output
+12 VDC - BATT +
-12 VDC - GND
Relay 3 Jumper
1&2 = NO
3&4 = NC
3
4
J1
1
2
Postal Lock
Tamper Input:
NC
Com
RELAY 3
RELAY 2
RELAY 1
The 2112 operates ONLY on 16.5 VAC.
DO NOT power the 2112 with 24 Volt
transformer or source voltage.
Use the supplied power transformer, 16.5
VAC, 20 VA (or UL listed equivalent) to
power the 2112. DO NOT power any other
devices (electric strikes, magnetic locks
etc.) from the 2112’s power transformer.
J1 jumper needs to
be set for RELAY 3
when used.
16 VAC IN Power Input
Polarity does not matter.
Do Not Connect To A
Receptacle Controlled
By A ON/OFF Switch.
Supplied
Transformer
Wire Size Max Distance
18 AWG
16 AWG
100 ft
200 ft
Wire Run Table
If you need postal service access,
use the DoorKing Postal Lock Box
sold separately (P/N 1402-080).
GND
TAMPER SW
POST
AL
LOCK BOX
Low Voltage Surge Suppressor
DoorKing Surge Suppressor P/N 1878-010
(or equivalent) is optional but highly
recommended to protect against power
surges. See next page.
“BAT +” 12 VDC Back-Up Battery Input
Back-up battery power for the 2112.
DoorKing P/N 1801-008
“Normally Open”
Vehicular Gate Operator
Access Control Devices to RELAYs 1, 2, 3
Pedestrian Door/Gate
NO
Com
To Chosen
Relay
Com
NO or NC
Maglock
Electric
Strike
Magnetic locks or electric strikes must be
powered from a separate UL Listed power
transformer. DO NOT power strikes or
magnetic locks from the 2112 power
transformer. It is recommended to keep
power wire runs as short as possible.
Separate UL
Listed Power
Transformer
“Normally Open” - Electric Strike
“Normally Close” - Maglock
Wire Size Max Distance
18 AWG
16 AWG
100 ft
200 ft
Wire Run Table
WA
R
N
IN
G
M
O
V
I
N
G
G
A
T
E
C
A
N C
A
US
E
O
p
e
rat
e
g
at
e
o
n
ly
when
g
a
t
e
a
r
ea
i
s
i
n
s
igh
t
a
n
d
f
r
e
e
o
f
p
eo
p
le
a
n
d
o
b
st
ru
c
t
i
o
n
s
.
D
o
no
t
a
l
l
o
w
c
h
i
ldr
e
n
t
o
p
l
ay
in
g
a
t
e
ar
ea
o
r
o
per
a
t
e
g
a
t
e.
D
o
not
s
t
an
d
i
n g
a
t
e
pa
t
h
o
r
w
a
l
k
t
hro
ug
h
p
a
t
h
w
h
i
le
g
a
t
e
i
s
m
o
v
i
ng
.
R
e
a
d
o
w
n
e
r
’
s
m
an
ua
l
a
n
d sa
f
et
y
ins
t
r
u
c
t
i
o
n
s
.
S
E
R
I
O
U
S
I
N
J
U
R
Y
O
R
D
E
A
T
H
C
L
A
S
S
C
E
RT
I
F
I
E
D
T
O
C
A
N/
C
S
A
C
2
2
.
2
N
O
.
2
4
7
C
O
N
F
ORM
S
T
O
A
NS
I/
U
L
-
3
2
5
V
EH
I
C
U
L
A
R
G
A
T
E
O
P
E
RA
T
OR
HP
5
3
3
8
2
M
O
D
E
L
S
ER
I
A
L
V
O
L
T
SP
H
A
S
E
A
M
P
S
6
0
H
z
M
A
X
G
A
T
E
L
O
A
D
D
oo
r
K
in
g
,
I
n
c
.
,
I
n
g
l
e
w
o
o
d,
C
A
2.1 Terminals TB1, TB2, TB3, TB4
Be sure to
properly ground
board. See next
page for acceptable
grounding sources.
Ground
12 AWG Min.
Output
16.5
VA
C
20
VA
The Tamper input is not defined yet.
The concept is that in input here
will generate some type of
transaction or notification on the
app. Maybe tie in with gate operator
to show that the gate is held open,
but we have not defined this yet
TB2 terminal
descriptions
NOT USED
1234567891012345678910