9150-065-M-5-18
3
Quick Guide - 2
FULL OPEN
NC
NO
1
2
3
4
5
6
7
8
9
10
15
10
6
5
Low Voltage Common
LED Indicator Output
Dry Relay Contact
Gate Tracker - Data
Gate Tracker - Busy
Entrapment Alarm
Alarm Reset
3-Button Close
(DoorKing 3-Button station ONLY)
Exit Loop Logic Output
(DoorKing Loop Detectors ONLY)
3-Button Full Open
(DoorKing 3-Button station ONLY)
Dry Relay Contact
Full Open
Partial Open
Standard Reverse or Stop
Not Used
Low Voltage Common
Full Open
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
• When gate is closed, this input will fully open
gate.
• When gate is open and auto close timer SW 1,
switch 2 is turned ON, input will re-set and hold
timer.
• When gate is open and auto close timer SW 1,
switch 2 is turned OFF, input will close gate.
• When gate is closing, input will reverse gate.
ON
1 2 345678
SW 1
17
Provides 24 VDC, 250 ma. maximum to power
LED. Operation of LED is dependent on setting of
SW 1, switches 4 and 5 (See page 21).
ON
12345678
SW 1
Operation of relay is dependent on
setting of SW 1, switches 4 and 5.
Relay contacts can be set for Normally
Open (NO) or Normally Closed (NC)
operation.
Contact rating is 1 amp
maximum at 24-volts DC.
ON
12345678
SW 1
NO
NC
4
• This input ONLY fuctions when gate is fully
opened or in the closing cycle.
• When gate is open: auto close timer SW 1,
switch 2 is turned ON, input will re-set and hold
timer.
• When gate is open: auto close timer SW 1,
switch 2 is turned OFF, input will prevent gate
from closing.
• When gate is closing: input will stop gate when
SW 2, switch 2 is ON.
• When gate is closing: input will reverse gate
when SW 2, switch 2 is OFF.
ON
1 2 345678
SW 2
ON
1 2 345678
SW 1
Jumper Wire SW 2, switch 2 OFF (Dual Operators only)
Jumper Wire SW 2, switch 2 OFF (Exit Loop Partial Open)
For long gate application. SW 2, switch 3
must be OFF. Same operation as #4
terminal above but will only open a closed
gate 14-Ft. or reverse a closing gate to the
14-Ft. open position.
ON
123 45678
SW 2
ON
1 2345678
SW 2
- Terminal #10 connected to terminal #5 will PARTIALLY open
plug-in exit loop detector (Single channel) for a single operator.
- Terminal #10 connected to terminal #4 will FULLY open
bi-parting gates. Dual operators ONLY using DoorKing’s
plug-in DUAL channel loop detector. (Page 32).
• lf SW 2, switch 1 is ON, the plug-in exit loop detector
(Single channel) will FULLY open the gate (Normal Setting).
Single operator use ONLY.
• lf SW 2, switch 1 is OFF, the normal exit loop port
function is used by terminal #10:
QUICK GUIDE: Terminal Descriptions
See page 30 for terminal wiring.
UL 325
Terminal
Pages
25-27
24 VAC - 250 mA max.
(See note below)
Terminal #3 Note:
Exceeding 250 mA of power from
this terminal may cause the circuit
board transformer to overheat,
causing intermittent problems.