9150-065-M-5-18
30
ON
E
X
L
O
FULL OPEN
DOORKING
4602-010
NC
NO
1
2
3
4
5
6
7
8
9
10
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
WARNING
M
O
VI
NG
GA
T
E
CAN
CA
USE
O
pe
r
a
t
e
g
a
te
onl
y
wh
e
n
ga
te
a
r
e
a
i
s
i
n
s
i
g
h
t
a
n
d
fr
e
e
o
f
pe
opl
e
a
nd
ob
s
tr
uc
ti
o
n
s.
D
o
no
t
a
l
l
ow
c
hi
l
dr
e
n
to
p
l
a
y
i
n
ga
te
a
r
e
a
or
o
pe
r
a
te
ga
t
e
.
D
o
no
t
s
ta
nd
i
n
g
ate
pa
th
o
r
wa
l
k
th
r
ou
g
h
pa
t
h
whi
l
e
ga
te
i
s
mo
v
i
n
g
.
R
e
a
d
ow
ne
r
s
ma
nu
a
l
a
nd
s
a
fe
ty
i
n
str
u
c
ti
o
n
s
.
S
ER
IOU
S
IN
JU
R
Y
O
R
D
EA
TH
CL
AS
S
CE
R
T
IF
IE
D
T
O
CAN
/
CSA
C
22
.
2
N
O
.
2
47
C
O
N
FO
R
M
S
T
O
AN
SI/U
L
-
3
2
5
VEHI
CU
L
AR GA
T
E
OP
E
R
A
T
OR
H
P
5
33
8
2
M
O
D
E
L
SE
R
IAL
V
O
L
TS
PH
AS
E
A
M
PS
6
0
H
z
MAX
G
A
T
E
L
O
A
D
D
oor
Ki
ng,
I
nc
.
,
I
n
gl
ew
o
o
d
,
CA
ON
ON
REVERS
E
S
EN
S
ITIVIT
Y
REV
ER
S
E
L
OOP
EXIT
L
OOP
KE
Y
SWITC
H
DOOR
K
IN
G
46
0
2
-
01
0
S
W1
S
W
2
OP
EN
TIMER
N
C
1
2
3
4
5
N
O
5.2 Control Wiring for Single/Primary Operator
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone
Entry
Emergency
Open
Note:
All stand-alone and
telephone entry
devices must use a
separate power
source.
#2-Full Open
Com
Com
Com
Relay -
#2 - Full Open.
#5 - Opens 14-feet.
Relay N.O. - #2 - Full Open.
#5 - Opens gate 14-feet.
250 mA
max.
3-Wire Radio Receiver
ON
123 45678
SW 2
SW 2,
switch 3
must be
OFF.
Relay Com
24 Volt Com
24 Volt - 250 mA max.
4-Wire
Receiver
#5 Terminal Note (Single Operator Only):
Any opening device connected to terminal #5
will open the gate to the partial open 14-ft setting.
External entrapment protection devices will also
open the gate to the partial open setting. If the
Inherent Reverse Sensor gets activated during the
close cycle, it will always fully open the gate.
24 volt
Full Open
Full Open
Partial Open
Important: Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where the user is prevented from
reaching over, under, around or through the gate to operate the controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police,
EMS) may be placed at any location in the
line-of-sight of the gate.
UL 325
Terminal
Pages 25-27
Red Full Open
Green Close
White Com
3-Button Control Station DoorKing ONLY
#4-Connected device fully opens gate.
#5-Connected device opens gate 14-feet.
Terminal #3 Note:
Exceeding 250 mA of power from
this terminal may cause the circuit
board transformer to overheat,
causing intermittent problems.