- 35 -
LP Engine G430(3.0L) Troubleshooting
Problem Probable Cause Probable Solution
Will Not Start/FCV Fuel container empty Fill fuel container
Staying On
Do not exceed 80% of liquid capacity.
Liquid valve closed Open liquid valve slowly
Excess flow valve closed Reset excess flow valve
Close liquid valve
Wait for click sound
Open valve slowly
Plugged fuel line Remove obstruction from fuel line
Close liquid fuel valve
Using caution, disconnect fuel line
Clear obstruction with compressed air
Re-connect fuel line
Leak test
Clogged fuel filter Repair/replace as required
Close liquid fuel valve
Using caution, disconnect fuel line
Remove/replace filter element
Clean fuel filter housing
Open liquid fuel valve
Leak test
Faulty vapor connection Check connection
between pressure regulator
No holes in hose
and carburetor
Clamps must be tight
Watch for kinked and/or pinched
and/or collapsed hose
Fuel lock malfunction
Check circuit wiring
Check safety switch
Check fuelock
Repair/replace fuelock as required
Pressure regulator Test pressure regulator operation
malfunction
Use test kit
Install primary pressure gauge
Install secondary pressure gauge
Crank engine and observe readings
on pressure gauges
Compare readings to specifications
If readings are out of spec
repair/replace pressure regulator

Table of Contents