LP Engine G430(3.0L) Troubleshooting
Problem Probable Cause Probable Solution
Poor High Speed Restricted exhaust system Check exhaust system
Performance/Lean
Measure exhaust back-pressure
Condition
Compare to specs
Engine mechanical See Troubleshooting section
Excessive Fuel Carburetor malfunction Check carburetor
Consumption/LPG
Remove air/gas valve assembly
Exhaust Smell/Closed
Clean air/gas valve and carb throat
Loop System Not
Check diaphragm for holes/damage
Working
Check air/gas valve for wear/damage
Repair/replace as required
Incorrect ignition timing Check ignition timing
setting
Measure timing @ time position
Measure timing advance @ run position
Incorrect full load air/fuel duty Verify full load air/fuel duty cycle
cycle
Engine mechanical See Troubleshooting section
Pressure regulator Test pressure regulator operation
malfunction
Use test kit
Install primary pressure gauge
Install secondary pressure gauge
Crank engine and observe readings on
pressure gauges
Compare readings to specifications
If readings are out of spec repair/replace
pressure regulator
Air filter clogged Check air filter
Clean/replace as required
Weak ignition miss fire See ignition system
Vacuum Leak Replace fuel system vacuum hoses
Fuel pressure too high Replace/rebuild regulator.
Exhaust system leaks Repair exhaust system
Oxygen sensor failure Replace/reconnect oxygen sensor
FCV failure Replace/reconnect FCV
Commander failure Replace/reconnect commander