7
ED50/ED100/ED250 09-2021DL4616-011
dormakaba ED50/ED100/ED250 Owner's Manual
Overhead concealed header
Chapter 4
.. Full energy automatic swing door safety
information label.
This AAADM label (Fig. ..) outlines safety checks that
should be performed daily on a swing door controlled by
an ED/ED OHC operator configured for full
energy operation (ANSI/BHMA .).
.. Safety information label location.
Place label in a protected, visible location on door frame,
near program switch panel if possible.
.. Annual compliance section of label.
This section of label is only completed on automatic
swing doors that comply with ANSI/BHMA A.
standard and pass inspection by an AAADM certified
dormakaba USA Inc. technician.
.. Additional annual compliance inspection labels.
Place additional labels (Fig. ..) over annual
compliance inspection section of safety information
label.
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE: _____________
by AAADM Certified
Inspector
Number: ____________
Fig. 4.1.2 Annual
compliance
label, full
energy
SAFETY INFORMATION
Automatic Swinging Doors
. Walk toward the door at a
normal pace. The door
should open when you ar
about 4 feet from the door.
. Stand motionless on
threshold for at least 10
seconds. The door shoul
. Move clear of the area. Th
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
. Repeat steps 1 through 3
from other direction if door
is used for two way traffic.
. Inspect the floor area. It
should be clean with no
loose parts that might caus
user to trip or fall. Keep
traffic path clear.
. Inspect door's overall
condition. The appropriat
signage should be present.
. Have door inspected by a
at least annually.
AAADM
American Association of Automatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualified automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks,
in addition to those in the
Owner’s Manual, should be
made each day and after any
loss of electrical power
.
Fig. 4.1.1 Full energy safety
information label
. Safety information label, full energy swing doors (ANSI/BHMA A.)
AAADM safety information labels