dormakaba ED900 Setup and Troubleshooting Instructions Appendix A
A. Driving parameters – detail
Parameter
Value
range
Units
Factory
setting
Description
Opening speed, automatic mode.
. Opening speed refers to automatic mode, speed can be adjusted using this parameter.
. Internal monitoring system checks if parameter setting is admissible. If setting exceeds
admissible value, the setting is alternately displayed with the permissible value.
. After parameter set, verify setting meets ANSI/BHMA A. (low energy)
standards. See Chapter .
*Maximum opening speed °/s in low energy mode.
 - * °/s 
Closing speed, automatic mode.
. Closing speed refers to automatic mode, speed can be adjusted using this parameter.
. Internal monitoring system checks if parameter setting is admissible. If setting exceeds
admissible value, the setting is alternately displayed with the permissible value.
. After parameter set, verify setting meets ANSI/BHMA A. (low energy)
standards. See Chapter .
*Maximum closing speed °/s in low energy mode.
 - * °/s 
Hold open time, automatic mode.
. Hold open time starts once all internal, external, safety and push and go inputs have
been opened or dropped, and door is in an open position.
. Hold open time values from  to  are set in increments of  second.
. Hold open time values greater than  seconds are set in increments of  seconds.
. In low energy mode, a minimum hold open time of  seconds is required.
. Hold open time can be re-triggered.
 -  s
Night-bank hold open time.
. Night-bank (key switch) hold open time is set using this parameter.
. Night-bank Hold open time starts once contact on night-bank activator input is
opened and door is in an open position.
. Night-bank hold open time can be re-triggered.
 -  s 
Hold open time, manual opening.
. Default hold open time of  second that follows every manual opening of door can be
adjusted using parameter do.
. Hold open time starts when door is released.
 -  s
Wall masking on door hinge side.
. Wall masking required if door opens against an obstacle.
. When door reaches set wall masking angle, system will ignore signal from safety
sensor on door swing (hinge) side.
. The wider the detection range of safety sensor used, the greater the area must be in
which system has to ignore sensor's emitted signal. To insure personnel safety, it is
advised to keep this range as small as possible.
. If set wall masking angle is exceeded when door is being opened, a rapidly flashing dot
appears in top left hand corner of  digit display.
. Rapidly flashing dot disappears when door angle drops below set wall masking angle.

 -  ° 
A.. Driving parameters detail.
Appendix A - Driving parameters

Table of Contents

Other manuals for Dormakaba ED50LE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dormakaba ED50LE and is the answer not in the manual?

Dormakaba ED50LE Specifications

General IconGeneral
Opening SpeedAdjustable
Closing SpeedAdjustable
Opening WidthAdjustable
Product TypeElectromechanical Door Operator
Operating ModesAutomatic, Manual
Safety FeaturesObstacle detection
FinishAnodized aluminum
Holding Force AdjustmentYes

Related product manuals