Page #14 background imageLoading...
Page #14 background image
14
8
Z-
PG input Z- phase
9
PE
Shielding
Line-saving
encoder
H, K
2
5V
PG power supply
+5V
1
2
35
6
10
11
13
1415
Compatible encoder
line: BD-017
3
0V
PG power supply
+0V
4
A+
PG input A+ phase
7
A-
PG input A- phase
5
B+
PG input B+ phase
8
B-
PG input B- phase
6
Z+
PG input Z+ phase
9
Z-
PG input Z- phase
1
PE
Shielding
Encoder types: B non line-saving 2500 line, H line-saving1024 line, E line-saving 2500 line, K line-saving 5000 line.
2.2.2 Motor Power Terminal appearance and signal
Motor Flange
Terminal Mark
Name
Function
Appearance
60/80/90
1
U
Motor U phase power
2
1
4 3
Compatible power line:
DA-002
2
V
Motor V phase power
3
W
Motor W phase power
4
PE
Casing
110/130
3
U
Motor U phase power
1
2
4
3
Compatible power line:
DB-002, DC-002
DD-002, DE-002
2
V
Motor V phase power
4
W
Motor W phase power
1
PE
Casing
Notes: The above table is based on the terminal at motor side, so please pay attention to it when connecting wire.