3.2.2 Output signals
(1) Output signal configurations
Factory default output signal configurations can be modified by PA149~PA150.
parameter
number
Name
Set range
Default value
Effective
time
PA149~PA150
Control terminal output
signal selectection
065535
PA149 =12816 (0x3210)
PA150 =30292 (0x7654)
Immediately
Code
Output signal functions
0
Servo ready (S-RDY)
1
Servo alarm (ALM)
2
Brake release (BRK_OFF)
3
Position reached (COIN)
4
Torque reached (TLC)
5
Zero speed signal (ZSP)
6
Homing reached (RZ)
PA149~PA150 can configure 6 output signal pins except ZO, as shown below:
4
0123
3 7 5
27
4567
28
0
1
2
3
4
5
6
7
代号
接点功能
S_RDY
ALM
BRK_OFF
TLC
ZSP
COIN
PA149PA150
默认情况下
CN2引脚号
PA148=0x7654=30292
PA147=0x3210=12816
十六进制数
——
RZ
(2) Output signal status selctions
parameter
number
Name
Set range
Default value
Effective time
PA66
Output signal status
select
0~65535
6