Aerotest Alpha

Questions and Answers

  • L
    Lisa CarterAug 18, 2025
    What to do if there is a large measuring error with Dräger Test Equipment?
    • C
      Carlos Wood MDAug 18, 2025
      If you are getting a large measuring error, there could be a couple of reasons. First, check that the Dräger tube is inserted in the correct Dräger tube holder. Second, the Dräger tube holder might be dirty or loose. Try cleaning the Dräger tube holder, and replace it if necessary.
  • M
    munozmichelleAug 20, 2025
    What to do if Dräger Aerotest Alpha Measuring Instruments show a major measurement fault?
    • A
      Amy GordonAug 20, 2025
      If you're experiencing a major measurement fault with your Dräger Measuring Instruments, there are a few potential causes and solutions: * First, check that the tube is inserted in the correct holder. * Second, the tube holder might be dirty or loose; try cleaning or replacing it. * Finally, a blocked feed system can cause the wrong volumetric flow. To resolve this, unscrew the tube holder from the measuring unit and use compressed air to clear the feed insert from both sides.
  • A
    Anna PooleAug 23, 2025
    Why is the relief pressure deviating from 3 bar in Dräger Measuring Instruments?
    • M
      Mark ChenAug 23, 2025
      If the relief pressure is deviating from 3 bar on your Dräger Measuring Instruments, it indicates an issue with the O pressure regulator 2. The solution is to readjust it to a 3 bar relief pressure.
  • A
    Anthony BakerAug 26, 2025
    What to do if the compressed air connection is leaky on Dräger Measuring Instruments?
    • J
      John SchmidtAug 26, 2025
      If you notice a leaky compressed air connection on your Dräger Measuring Instruments, it's likely due to a defective sealing ring. You should check the sealing ring and replace it if necessary.
  • D
    diane88Aug 28, 2025
    What to do if the tube is not firmly seated in the tube holder of Dräger Aerotest Alpha?
    • T
      tiffanyhayesAug 28, 2025
      If the tube isn't firmly seated in the tube holder of your Dräger Measuring Instruments, the tube holder is likely worn. Replace the tube holder to resolve this issue.
  • D
    Deanna Griffin DVMAug 30, 2025
    How to fix a tube end that is not cleanly scratch marked and broken off in Dräger Aerotest Alpha Measuring Instruments?
    • U
      uedwardsAug 30, 2025
      If the tube end isn't cleanly scratch marked and broken off in your Dräger Measuring Instruments, this is probably because the tube opener is blunt. Replace the tube opener to fix this.
  • K
    Kevin HoffmanSep 1, 2025
    Why is the compressed gas connection leaky on my Dräger Test Equipment?
    • J
      jwilliamsSep 1, 2025
      A leaky compressed gas connection is often due to a defective sealing ring. Check the sealing ring and replace it if necessary.
  • B
    Brian DuarteSep 4, 2025
    What to do if the manual connection cannot be loosened on Dräger Test Equipment?
    • P
      Peter BeltranSep 4, 2025
      If the manual connection is stuck, it may be subject to pressure. Bleed the connection to release the pressure.
  • D
    David OliverSep 7, 2025
    Why is the safety valve releasing air on my Dräger Test Equipment?
    • T
      Timothy PerrySep 7, 2025
      If the safety valve is releasing air, it's possible the piston is leaky. Repair the pressure reducer.
  • P
    Patricia SmithSep 9, 2025
    What to do if the dosing unit is leaky in Dräger Test Equipment?
    • D
      Donna WoodSep 9, 2025
      If the dosing unit is leaky, the seal may be defective. Replace the sealing ring to resolve this issue.

Summary

For Your Safety

Whats What

Description and Intended Use

Preparation

Use

After Use

Technical Data

Bubble Test

Storage

Troubleshooting

Maintenance Intervals

Order List

Dräger Aerotest Alpha Specifications

General IconGeneral
Measurement Range N2O0 - 100%
Storage Temperature-20 - 60 °C
Target GasO2, CO2, N2O, Anesthetic Agents
Measured GasesCO2
Measurement Range O20-100%
Power SupplyRechargeable battery