Dräger X-am 7000 Specifications

General IconGeneral
TypePortable gas detector
DisplayLCD with backlight
Ingress ProtectionIP67
Humidity10 to 95% RH, non-condensing
SensorsElectrochemical
AlarmVisual, Audible, and Vibration
Power SupplyRechargeable NiMH battery or Alkaline batteries
Operating Temperature-20°C to +50°C
Data LoggingYes
Gases DetectedOxygen (O2), Combustible gases (LEL), Carbon monoxide (CO), Hydrogen sulfide (H2S)

Summary

Dräger X-am 7000 Technical Handbook

Introduction and Safety Information

Overview of the device and explanation of safety symbols used in the manual.

Menu Navigation and Core Functions

Menu Structure and Navigation

Overview of the menu system, navigation symbols, and structure.

Basic Operating Procedures

Instructions for switching to menu mode and entering passwords.

Quick Menu Functions

List of functions that can be activated or deactivated in the Quick Menu.

Information Menu Details

Instrument Information

Details on instrument status, notices, and faults.

Sensor Information

Information on sensor calibration status, including last and next calibration dates.

Exposure Information

Details on short-term and time-weighted average exposure values.

Calibration Procedures

Calibration Menu Overview

Overview of available calibration types: fresh air, mixed-gas, bump test.

Fresh Air Calibration

Procedure for calibrating the instrument in fresh air to improve zero-point accuracy.

Mixed-Gas Calibration

Procedure for calibrating multiple sensors simultaneously using mixed gas.

Sensor Calibration and Adjustment

Step-by-step guide for calibrating and adjusting individual sensors.

Device Settings and Configuration

Instrument Settings

Configuration of instrument parameters like leakage mode, time, keys, alarms, and telemetry.

Sensor Settings

Configuration of individual sensors: gas type, calibration intervals, exposure parameters.

Exposure Settings

Settings for data logger configuration and exposure evaluation parameters.

Application Mode

Configuring Application Modes

Customizing device and sensor settings for specific applications via software.

Troubleshooting and Maintenance

Faults, Causes, and Remedies

Comprehensive guide to identifying and resolving instrument faults and error messages.

General Care

Basic instructions for cleaning the instrument and its components.

Maintenance and Component Replacement

Procedures for inspections, calibration intervals, and replacing sensors, pumps, or power packs.