Use | en
Instructions for use | Panorama Nova 15
Full face masks with "PC" or "PC/CC" visors:
Mask/helmet combinations may only be used in hazardous areas with a water
screen.
3.6 Type-identical markings
The facepieces are marked differently:
4 Use
4.1 Conditions for use
The mask/helmet combination needs to be carefully adapted to the equipment
wearer (adjustment of the adapter slot and internal helmet components) due to
its structure. The mask/helmet adapter must be easy to adjust.
The following conditions must be met if the full face masks are used with a
respiratory filter or a powered air-purifying respirator:
The ambient conditions (particularly the types and concentrations of
contaminants) must be known. Use corresponding respiratory filters.
Only use self-contained open-circuit breathing apparatuses or air line
breathing apparatuses in cases where the contaminant is unknown.
Only use filtering devices if the air does not directly endanger the health or
life of the user.
It must be ensured that the ambient atmosphere cannot change for the
worse.
Do not use the filtering devices if contaminants with low warning properties
(low-odour, tasteless, no irritation of eyes and airways) are suspected. A
decreasing protective effect of the filtering device cannot be determined in
this case.
Do not use filtering devices for entering unventilated tanks, mines, canals,
etc.
Do not use filtering devices in oxygen-enriched atmospheres.
The oxygen content of the ambient air must not fall below the following limit
values:
At least 17 Vol% oxygen in all European countries except in the
Netherlands, Belgium and the UK
At least 19 Vol% oxygen in the Netherlands, Belgium, the UK, Australia
and New Zealand
In other countries, observe the applicable national regulations.
4.2 Before first use
Check that the facepiece is leak-tight before using it for the first time (see
Technical Manual 9300782 at www.draeger.com/ifu).
I M1
II 1 G IIB T6
1)
II 1D
1) –30 °C ≤ Ta ≤ +60 °C
I M1
II 1 G IIA T6
1)
II 1D
Front port P, PE, ESA, RA
Mask/helmet adapter S
Mask body EPDM or Si
EN 136:1998 CL 3+
CExxxxx (notified body in Europe)
Visor (fire brigade) PC, PC/CC or L (Triplex), F
Visor frame K/rt, K/sw
Elastic straps EPDM or Si