LSE01 LoRaWAN Soil Moisture & EC Sensor User Manual 14 / 30
AT+CFM
Any
05
4
INTMOD
Any
06
4
Examples
Set TDC
If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), while type
code is 01.
Payload: 01 00 00 1E TDC=30S
Payload: 01 00 00 3C TDC=60S
Reset
If payload = 0x04FF, it will reset the LSE01
CFM
Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0