D-1000B HEATER
Outdoor Use Only
OPERATIONS & MAINTENANCE MANUAL
ISO 9001: 2000 Registered
Quality Management System
33 Kings Highw
ay, Orangeburg, NY 10962 Phone: 845-359-6066
Fax: 845-365-2114
Hotline: 800-977-3647
DHS Manual Part Number: 1006395 Web: www.drash.com
Revision Date: 01 APRIL 2010 Email: drash@drash.com

Table of Contents

Questions and Answers

  • D
    Dana MurrayAug 10, 2025
    How to troubleshoot a Drash Heater when the motor won't start and there's no ignition?
    • A
      aaron22Aug 10, 2025
      If the Drash Heater motor does not start and there's no ignition, first, ensure the heater is properly connected to a 120V, 60Hz grounded power supply. Then, verify the heater control is correctly set. If you're using a thermostat, ensure the selected temperature is higher than the current room temperature. If issues persist, the thermostat or control device may be defective and require replacement.
  • W
    Wendy ElliottAug 15, 2025
    What to do if the Drash D-1000B Heater motor starts but there is no ignition or it cuts out?
    • M
      Ms. Teresa MurphyAug 15, 2025
      If the Drash Heater motor starts but there is no ignition, verify the connection of the H.T. Ignition Cables to the electrodes. Also, inspect the Electric Motor- Fuel Pump plastic coupling. If the issue continues, check the electrical connection of the Solenoid. Consider replacing the Ignition Control Assembly, Pressure Switch, or cleaning/replacing the Photocell, fuel filter, or fuel nozzle.
  • C
    Connor SandersAug 20, 2025
    Why does my Drash D-1000B Heater start but emit smoke?
    • E
      Edward DawsonAug 20, 2025
      If your Drash Heater is emitting smoke, ensure that the air inlet and outlet are free of any obstructions. Also, check the setting of the combustion air flap. If the problem persists, drain and flush the fuel tank with clean fuel to remove any contamination. Consider cleaning the burner flange.
  • G
    Gary OdomAug 25, 2025
    What to do if my Drash Heater motor starts but there is no ignition or it cuts out?
    • L
      Lisa ReyesAug 25, 2025
      If the motor starts but there is no ignition, or the heater cuts out, consider these potential causes: * A defective electric igniter. Check the connection of the H.T. leads to electrodes and transformer. * A defective air pressure switch. Replace the air pressure switch. * A defective flame control box. Replace the control box. * A defective photocell. Clean or replace the photocell. * Insufficient or no fuel reaching the burner. Check the state of the motor-pump plastic coupling. * Fuel contamination or water in the fuel. Drain and flush the fuel tank with clean fuel.
  • J
    Jeremy WilliamsAug 30, 2025
    How to troubleshoot a Drash D-1000B Heater when the motor does not start and there is no ignition?
    • R
      robert10Aug 30, 2025
      If the motor of your Drash Heater doesn't start and there is no ignition, here are some things to check: * **Power Source:** Ensure the heater is properly connected to a 120V/60Hz grounded power supply. * **Thermostat Settings:** Verify the heater control is correctly set. If using a thermostat, ensure the selected temperature is higher than the current room temperature. * **Defective Components:** The thermostat or another control device, the electrical motor, or the condenser might be defective and require replacement.
  • R
    ramseyleslieSep 4, 2025
    Why does my Drash D-1000B Heater motor start but emit smoke?
    • C
      Charles FowlerSep 4, 2025
      If your Drash Heater's motor starts but it emits smoke, it could be due to: * Insufficient combustion air. Ensure the air inlet and outlet are free of any obstructions. * Too much combustion air. Check the setting of the combustion air flap.