D-1000B Heater Operations & Maintenance
GENERAL 1-4 DHS SYSTEMS LLC
No rights are conveyed except as indicated in the legend on the inside front cover of this document.
1.4.7 Performance
With a watertight control panel, the D-1000B heater was designed to operate in all different types of environmental
conditions. A pre-heated fuel filter allows heater to work continuously in extreme low temperatures. When operating the
D-1000B heater, the noise level when measured at a distance of 3 feet (0.92 meters) from the control panel is 76dB. With
the remote thermostat / CO detector attached, the heater may be operated remotely from within the shelter. The D-1000B
has a fuel consumption rate of 0.81 US Gallon per hour (3.07 liters per hour), approximately 12 hrs of continuous run-time
without refueling.
1.4.8 Auxiliary Equipment
Each D-1000B heater will include the following auxiliary equipment:
An exhaust stack.
Two heater ducts (supply and return); 12” dia x 15’ L (0.3m dia x 4.5m length) with transport bags.
A remote control Thermostat / CO (Carbon Monoxide) Detector with a 26 foot (7.9m) power cord.
An Operational and Maintenance Manual.
1.5 Specifications
Color: Green
Overall Dimensions:
Length: 53.2 inches (1.4 meters).
Width: 23.8 inches (0.6 meters).
Height: 32.3 inches (0.8 meters) with exhaust stack installed 29.5 inches (0.7 meters without exhaust stack).
Flue Diameter: 5.9 inches (14.9cm).
Weights:
Dry: 165 lbs (75kg) (without accessories).
Wet: 242 lbs (109.7kg).
Heater Ducts: 27 lbs (12.2kg) each.
Input Power:
Power Supply: 120V, 60Hz (Variable Voltage: 220V, 50Hz; 110V, 50Hz).
Power Consumption: 520W.
Fuse: 10A.
Heat Input Capacity: 110,000 BTU/hr.
Air Flow: 880 CFM.
Nozzle: 0.55 GPH - 80°B.
Pump Pressure: 170 psi.
Operable Temperature:
Range: -40°F to 40°F (-40°C to 4.5°C).
Fuel System:
Tank Capacity: 10.8 US Gallon (40.8 liters).
Fuel Types: JP8 or Diesel.
Certification:
CSA B140.0-03 & B140.8-1967 Certified.
UL 733 Compliant.