07-01706B 2010-02 4 Dri-Eaz Products
display will read PUMP PURGING with a numeral
countdown.
Main menu display
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
displays. This is part of the unit’s self-diagnosis
procedure and no user intervention is required.
Once the self-diagnosis is complete, the display will
show the following information:
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see “Job Hours Reset”
below). The second line of the display alternates
between inlet temperature and inlet humidity.
When fitted, the optional LGR1800i wireless transmitter
continuously seeks a connection with a HygroTrac
gateway. When a connection is established, a wireless
symbol
appears in the lower right corner of the
display.
No information is presented on the display when the unit
is not plugged in.
User settings menu
A number of settings may be changed by the user.
System information is also available. These items are
accessed by pressing the
DISPLAY MENU key. Each
press of the key will display the next parameter (see list
below). When you reach the parameter you wish to
adjust, press the
MENU SELECTON key to increase
the value. Press
DISPLAY MENU again to accept the
setting and re-start the display cycle. If no keys are
selected for 20 seconds the display will automatically
reset and return to the normal display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
JOB HOURS
RESET? >
Press to reset hours to zero. NOTE: When in
Humidistat mode, the unit will display HUMIDISTAT on
the top line during normal operation rather than JOB
HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET OUTLET
00° 00% 00° 00%
Shows current temperature and RH of inlet and outlet.
The HygroTrac system uses these values to calculate
grain depression.
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
to toggle between ON and OFF.
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode (see
above). Press
to change RH value at 5% increments.
Settings cycle upward through 90%RH and start again at
30%RH.
TEMPERATURE UNIT
C° >
Shows current temperature scale. Press to select
Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press to
select Spanish, German, French or English.
COIL TEMP
00°C
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
When optional remote sensor fitted, shows built-in
wireless transmitter number. The HygroTrac system
uses this to uniquely identify your LGR1800 unit. NOTE:
For convenience, this same number is shown on the
barcode label affixed to the control panel.
Press
to cycle through the following values: SENSOR
TYPE, SENSOR REVISION, and SENSOR CONF REV.
A Dri-Eaz service technician may ask you for these
values when diagnosing a problem.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
Error messages
If the LGR1800 onboard diagnostics discover a problem,
the unit will display an error message. If the unit is used
with the HygroTrac system, it will also transmit most