07-01706B 2010-02 5 Dri-Eaz Products
error messages to the user’s HygroTrac website. See
“Error Messages,” p. 6, for more information.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD. Unplug
the LGR1800 before performing any maintenance.
Never use a water hose or pressure washer to clean
coils, as water entering the electrical compartment
could cause a shock hazard.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Call Dri-Eaz for service on +44 (0)1908-611-
211.
Inspect and vacuum filter as needed. Keep a clean
filter in the unit at all times to protect internal
components from dust and other particulate build-up.
The LGR1800 is equipped with a 3M™ High Air-Flow
filter. The HAF filter may be vacuumed clean and reused
up to three times. Do not rinse or wash the HAF filter,
as it will reduce the effectiveness of the electrostatic
material.
Replace only with a new 3M HAF Filter (Dri-Eaz part
no. F372). For parts and service call Dri-Eaz Service
Department on +44 (0)1908-611-211.
CAUTION: Dust can cause the unit to overheat and
shut down. Do not operate when excessive dust or
airbourne particles are present, such as during
sanding or spray-painting. Inspect and clean air filter
elements and coils frequently.
IMPORTANT: Replace the HAF filter whenever 1)
it has been vacuumed clean 3 times or 2) it has
been used on a mould remediation job or
otherwise exposed to
potentially dangerous
contaminants.
Monthly
Check coils. Dirty coils can
cause the unit to overheat.
Clean when visibly dirty. See
Fig. E.
1. Unplug unit
2. Remove housing, locate
coils and allow coils to dry if
wet.
3. Vacuum coils surfaces until
clean, being careful not to let
the nozzle touch the fins, as
that may cause damage by
bending them.
Check catch basin tray, and clean when dirt and
debris are present.
1. Wipe clean with a rag.
Check drain hose.
1. Look for obstructions. Disconnect and clear any debris
present.
2. Reattach gravity drain hose.
Inspect filter cover
1. Remove the filter cover (this can be done without
removing the housing).
2. Vacuum off any visible dirt, or wash with mild soap
and water.
3. Let dry and put back in place.
Annually
Have the pump system inspected by the Dri-Eaz Service
Department on +44 (0)1908-611-211.
To access the LGR1800 pump, remove the four bolts
located at the bottom of the unit (Fig. F). Use a -in. nut
driver or socket.
TRANSPORT AND STORAGE
NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
IMPORTANT: Be sure to purge the water from the pump
reservoir before moving the unit. See the PURGE
function under “How to use the control panelon page 3.
Note that the unit must be
plugged in for the Purge
function to operate.
1. Do not expose the control
panel to moisture, snow or
rain when transporting in
uncovered vehicles.
2. Store and transport
securely to avoid any
damaging impact to internal
parts.
READ AND
SAVE THESE
INSTR
FIG. F: PUMP ACCESS PANEL
To access the
pump, remove
the four bolts
(circled) on the
lower panel.