07-01706B 2010-02 7 Dri-Eaz Products
TROUBLESHOOTING
FAULT CAUSE SOLUTION
operate
Unit not switched on.
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
not start
Unit needs 5 minutes before restart
Overload preventing start up
Switch off unit, wait 5 minutes before starting.Reduce
room temperature below 32°C.
Blower wheel
not turning
Obstructed blower. Remove duct ring and grill.
Remove obstruction.
Replace duct ring and grill.
but room not dry
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
continuously in
defrost mode
Increase room temperature.
function
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Airflow through unit is restricted
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as necessary.
If the problem you are experiencing is not listed here, call Dri-Eaz Service Department on +44 (0)1908-611-211.
SPECIFICATIONS
Model LGR1800 F432 (i)
Type Low grain refrigerant
Refrigerant R-410A
Use weight 42 kg
Dimensions
85 × 52,5 × 52,5 cm
Power 2.8 amps, 230 volts
Water removal AHAM
(80°F/60% RH)
35 liters / day
Water removal max.
(90°F/90% RH)
63 liters / day
Max process air 289 CMH*
Operating Range 1–32°C
Air filter 3M HAF filter (part no. F372)
Power cord
7.6 m
Construction Rotomolded polyethylene housing
Safety CE
Specifications are subject to change without notice. Some
values may be approximate.
CONTACT
Dri-Eaz Products, Ltd.
22 Plover Close
Interchange Park
Newport Pagnell MK16 9PS
United Kingdom
Phone: (0)1908-611-211
Fax: (0)1908-611-363
Dri-Eaz Products, Inc.
15180 Josh Wilson Rd
Burlington, WA 98233
United States of America
Phone: 360-757-7776 Fax:
360-757-7950
www.dri-eaz.com
Warranty information is available at www.dri-eaz.com.
MICROBAN® is a registered trademark of Microban
Products Company.