EasyManua.ls Logo

DROMONT Compacta - Dispensing Nozzles; Moistening the Humidifier Cap Sponge

Default Icon
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Compacta - User s Manual
Compacta User_en ed 1 Feb 05.doc
Page
29
of 34
picture
6-2
Canister filters
6.3.2
Dispensing nozzles
In case the dosing nozzles dry out, use a piece of cloth wrapped around a little nail or something
similar (with a maximum diameter of 3mm) and clean them one by one. Never use the cloth to
wipe the entire block because this causes a pollution of the nozzles and the accuracy of the color
will be affected.
6.4
Moistening the humidifier cap sponge
Depending on the type of colorant (e.g. water- universal or solvent based the sponge has to be
humidified with respectably alcohol or solvent.
For the Compacta the exchange of the sponge is very simple.
The replacement or cleaning of the sponge is possible by unscrewing anti clockwise the main bold
of the cap (see
picture
6-3
) by using an Allan-wrench.
WARNING
MAKE SURE THE EMERGENCY BUTTON I S PRESSED BEFORE
DOI NG THE ABOVE W RI TTEN PROCEDURE