Compacta - User s Manual
Compacta User_en ed 1 Feb 05.doc
Page
21
of 34
5.5
Connecting the computer.
If the customer as an option chooses the computer, the accompanying software (e.g. application
software, modem, printer etc) has already been installed. If this is not the case the installation
instructions that came with the computer have to be followed.
When the customer uses his own computer, it has to have the following features:
a)
1 serial port RS 232 for connecting the dispenser
b)
1 serial port RS 232 for connecting the scale
c)
1 serial port RS 232 for connecting the modem
d)
1 parallel port to connect the printer
5.6
Installing the Dromont Software
With every machine comes a (auto) installation CD that contains a software package.
On every CD the following programs are recorded:
a)
D_POS
for the formula manager (option)
b)
D_DSP
for the dispenser manager
c)
D_SET
for the setting parameter
d)
D_TST
for the I/O test
e)
D_DQC
for statistic control dosing (option)
f)
All the software manuals in electronic format
g)
User s Manual of the machine (CE Manual) in electronic format
For more information about software please refer to the Software Manuals.