23/27
9.4 SPECIAL FUNCTIONS:
1) LCD CONTRAST ADJUSTMENT: by Pressing ESC or OK during power on or immediately after a reset, you access the
menu for adjusting the contrast of LCD; hold down OK the contrast decreases, with ESC increases;
2) FLOW TOTALIZER DATA VISUALIZATION: with the VIP5 in standby mode, pressing the OK key will allow you to scroll
through the current average flow rate, or the total volume dispense in the last DAY, HOUR or TOTAL since last reset;
3) RESETTING THE FLOW TOTALIZER: during the visualization of the above parameters the flow can be reset by holding
the DOWN key;
4) TIME AND DATE: during standby, it is possible to view time and date by using the ESC key only if DATETIME
parameter is set on “enable” ;
5) EVENT LOG VIEWER: by holding the Up or Down key for five seconds it is possible to scroll through the Event Log.
(Available in version FW 2.xx onwards)
Time between two Lubrication Cycles within the
Lubrication Phase
Determines state at power on:
Start in Lubrication Phase
Resume from power down state
Informational value of how much lubricant is dispensed
per Lubrication Cycle
Information Unit for the flow value parameter used for
display purposes only
Counts, CubicC., Liters, Pints,
Gallons, Kilos, Grams
Minimum Flow Setting
Totally excludes flow alarm if null
How REMOTE ALARM is managed
Relay is powered off during alarm
Relay is powered On during alarm
Coded alarm is signalling
Determines what Alarm conditions should stop the VIP5
Lubrication cycles VIP5 Pro
Never stop the lubrication cycle
All but min Level stops the Vip5 pro
Only minimum level alarm stops the VIP5
Configuration for the input signal of minimum level
Setting a low level if you use 4-20mA input
Setting a high level if you use 4-20mA input
When resetting a low level alarm, grace period before
monitoring level inputs
Setting for max level signal
Setting for thermal protection signal
Max time for refilling activation after minimum level is
switched off
Drop-out delay after switching off the pump control
Enable or Disable the Real Time clock functions. Note: be
sure battery is connected
Date Time: Minute setting