Chapter 1
1.0 Quick Reference
The PowerSeries Neo Alarm System uses shortcut keys to access options or features on all models of keypads. When using an
LCD keypad, the PowerSeries Neo Alarm System additionally uses a menu based navigation system. The scroll keys can be used
to [Scroll] through the list of options contained within the current menu. For more information on keypads see: 2.0 “Understanding
your Keypad”. Lookup detailed information on any of the listed actions using the accompanying Section number.
Note:Some features must be enabled by installer.
Note:Bypass Groups are not permitted in UL listed installations.
Note:[*] - If configured by installer.
Status
Lights
Function Keys
Function
Keys
Status
Lights
Emergency
Keys
Emergency
Keys
Ready - Indicates system normal. Must be on to set system. All zones
must be secured or bypassed and the system unset for this light to activ-
ate.
Stay
Set
Fire Alarm
Set- Indicates system is set. If the Ready light and the Set light are both
on, an Exit Delay is in progress.
Away
Set
Medical
Alarm
Trouble - On indicates a system malfunction or tamper. Flashing indic-
ates that the keypad has a low battery condition. Follow the instructions
displayed or enter [*][2] to view trouble. Correcting the trouble turns
off the indicator.
Chime Panic Alarm
AC Power - Indicates AC Power is present. The AC Power light will
turn off when AC is absent.
Reset
Sensors
Quick
Exit
Action Press
Setting and Unsetting
Away Set
for 2 seconds + [Access Code*]
Stay Set
for 2 seconds + [Access Code*]
Night Set When set in stay mode [*][1] + [Access Code*]
No-Entry Setting [*][9] + [Access Code*]
Quick Set/Quick Exit [*][0]
Abort Setting Sequence [Access Code]
Bypassing - All bypass commands begin with [*][1] + [Access Code*]
Bypass Individual Zones [3 Digit Zone #]
Bypass All Open Zones [9][9][8]
Recall Last Bypass [9][9][9]
Clear Bypass [0][0][0] OR [Scroll] Bypass Options + [*] + [Scroll] Clear Bypasses + [*]
Program Bypass Group [3 digit zone #s] + [9][9][5] OR [3 digit zone #s] + [Scroll] Bypass Options
+ [*] + [Scroll] Prg Bypass Group + [*]
Load Bypass Group [9][9][1] OR [Scroll] Bypass Options + [*] + [Scroll] Bypass Group + [*]
Common Functions
Set Time and Date [*][6] [Master Code] + [0][1]
Turn Chime ON/OFF
[*][4] + [Access Code*] OR
Change Brightness
[*][6] [Master Code] + [1][2] +
Change Contrast
[*][6] [Master Code] + [1][3] +
Add/Delete User [*][5] + [Master Code] + [Access Code] + 1
Reset Smoke Detectors OR [*][7][2]
View Troubles
[*][2] + [Access Code*] +
View Alarms
[*][3] + [Access Code*] +
Perform System Test
[*][6] + [Master Code] + [0][4] +
Buzzer Volume
[*][6] + [Master Code] + [1][4] +
- 4 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo Power HS2016 and is the answer not in the manual?

DSC Neo Power HS2016 Specifications

General IconGeneral
Power Supply16.5 VAC, 40 VA
Operating Temperature0°C to 49°C (32°F to 120°F)
Event Buffer500 events
PGM Outputs2
CommunicationsPSTN
HumidityUp to 85% non-condensing