11
Additional Access Codes
To erase, add or change a user code, press [] to enter the functions list. Use the arrow
(< >) keys to scroll to the following message...
Press []. Display will read...
Enter the Master Code. Display will read...
Use the scroll keys (< >) to find the access code – indicated by
“02P” to “32P” – you wish to add, change or delete. Press the []
key to select the code you wish to alter. The display will read...
To add or change a code, enter the new code. Access codes must
be four digits unless otherwise indicated by your installer. Enter
digits 0 through 9 only.
To delete an access code, enter []. Once the 4 digit code or []
has been entered, the keypad sounder will beep 3 times and the
display will read...
The “P” means the code has been programmed. If there is no “P”
then that code is deleted. Press [#] to exit the code programming
function. The Master code cannot be erased.
Remember to record your new code(s) in “System Information” on page 2.
Zone Bypassing
The zone bypassing function is used when access is needed to part of the protected area
while the system is armed. Zones which are temporarily out of service due to damaged
wiring or contacts may be bypassed to allow system arming until repairs can be made.
Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is
armed. Bypassed zones are automatically cancelled each time the system is disarmed and
must be reapplied before the next arming.
NOTE: For security reasons, your installer may program the system to prevent you
from bypassing certain zones.
Bypassing zones reduces your security protection. If you are bypassing a zone due to
damaged wiring or contacts, please call a service technician immediately so that the
problem can be resolved and your system returned to proper working order.
Make sure that no zones are unintentionally bypassed when arming your system.
To bypass zones from an LED keypad:
Start with the system in the Ready state. Enter [][1][Zone number(s) to be bypassed].
Enter the zone(s) as a two-digit number from 01 to 32. As each zone is bypassed, the
corresponding zone light will turn ON. If a zone is bypassed by mistake, press that zone
number again and the zone light will turn OFF, indicating that the zone is not bypassed.
Press [#] to return to the Ready state.
To bypass zones from a PK/RFK5500 or LCD Message keypad:
To bypass a zone, the system must be in the Ready state. The display will read...
Press the [] key to enter the functions menu. The display will
read...
Press the [] key to enter the zone bypassing mode. The display
will read...
Use the arrow (< >) keys to find the zone to be bypassed and press
the [] key to select it. The display will read...
“B” will appear on the display to show that the zone is bypassed. To
unbypass a zone, enter the zone number; the “B” will disappear
from the display to show that the zone is no longer bypassed.
Press (*) for <>
Zone Bypass
Press (*) for <>
Access Codes
Enter Master
Access Code
[*] to Edit <>
User Code 01P
Enter New Code
1234 <>
[*] to Edit <>
User Code 01P
Enter Code to
Arm System
Zone Search <>
“Zone Name”
Zone Search <>
“Zone Name” B