1. The system will notify the Central Station that a walk test has begun.
2. Violate each detector (zone) in sequence. A squawk will occur at the keypad, all LEDs on
the keypad will flash and the violation will be recorded in the Event Buffer.
3. Restore zones. Press [,][6][Master Code] [8] to end the Walk Test. The system will notify
the Central Station that the walk test has been terminated.
NOTE: If a zone is not violated within 15 minutes of activating the Walk Test, the
system will automatically exit the Walk Test and resume normal operation.
Trouble Conditions
When a trouble condition is detected, the Trouble ( ) or System indicator will turn on, and
the keypad will beep every 10 seconds. Press the key to silence the beeps. Press
to view the trouble condition. The Trouble ( ) or System indicator will flash. The
corresponding trouble will be represented by numbers 1-8.
To view troubles from an LED Keypad:
A trouble will be indicated by the Trouble light (or System light on a PC1555RKZ keypad),
which will remain ON until the trouble condition is cleared. To view the type of trouble
condition, press [,] [2]. One or more lights will turn ON, indicating the various trouble
conditions.
To view troubles from a PK/RFK5500 or LCD Message Keypad:
From the Ready state, use the arrow (< >) keys to scroll to the following message:
Press [,] [2] key to view the trouble. The message will read...
Use the arrow (< >) keys to view which troubles are present on the
system. Once you have scrolled through the list of troubles, press
the [#] key to exit the Trouble Viewing mode and return to the Ready
state..
LED/
DIGIT
Trouble
Condition
Comments Action
1 Service Required
(Press [1] for
more details)
(1) Low Battery (2) Bell Circuit (3) System Trouble (4)
System Tamper (5) Module Supervision (6) RF Jam
Detected (7) PC5204 Low Battery (8) PC5204 AC Failure
Call for
service
2
Loss of AC
Power
If the building and/or neighbourhood has lost electrical
power, the system will continue to operate on battery
for several hours.
Call for
service
3 Telephone Line
Fault
The system has detected that the telephone line is dis-
connected.
Call for
service
4 Failure to Com-
municate
The system attempted to communicate with the moni-
toring station, but failed. This may be due to Trouble 3.
Call for
service
5 Sensor (or Zone)
Fault
The system is experiencing difficulties with one or more
sensors on the system. Press 5 to display the zone.
Call for
service
6
Sensor (or Zone)
Tamp e r
The system has detected a tamper condition with one
or more sensors on the system. Press 6 to display the
zone.
Call for
service
System Trouble
(*2) to View <>
View Trouble <>
“Trouble Message”