15
The zone light will turn OFF when the system is restored to normal (i.e. door or window
closed).
From an LCD keypad, the following message will be displayed when each zone is acti-
vated...
Use the arrow (< >) keys to view which zone is open. This message
will disappear when the zone is restored.
5. If the panel has any fire zones, activation will cause the alarm signal to sound in a
pulsed mode.
CAUTION: Do not use an open flame or burning materials to test a smoke or heat
detector. Contact your installer for information on safe methods of testing detectors.
6. When testing is complete, call and advise the monitoring station. Should the system fail
to function properly, contact your installer.
NOTE: Some features described above will not be functional unless enabled by your
installer. Please ensure that your installer has advised you which features are func-
tional on your system.
Door Chime Feature
The door chime feature is used to provide a tone from the keypad each time a door or
window is opened or closed. The doors and windows which will provide this indication are
programmed by your installer.
To activate the door chime from an LED Keypad:
Enter [][4] to turn the door chime feature ON and OFF. When the command is entered, the
keypad buzzer will beep 3 times if the door chime feature is enabled and will sound one long
beep if it is disabled. Press [#] to return to the Ready state.
To activate the door chime from an LCD Keypad:
Press [] to enter the function list, then scroll to find...
Press [] or [4] to enable or disable the Door Chime feature.
Press [#] to return to the Ready state.
Keypad Options
Keypad Sounder Control
LCD Numeric Keypad
The LCD keypad will allow you to select from 21 different keypad tones. From an LCD
keypad, enter [][6][Master Code], then use the arrow keys (< >) to scroll to the message
"Keypad Buzzer Control". Press [] to select. Use the arrow keys (< >) to scroll to the
desired keypad sound level. Press the [#] key to exit. This feature can be accessed on LED
keypads by holding the [] key.
LED or LCD5511 Numeric Keypad
Press and hold the [#] key until you reach the desired level of sound for the numeric keypad.
PK5500/RFK5500 Language Selection
Your keypad may have the capability to display messages in different languages.
1. Press and hold both keys simultaneously.
2. Using the keys, scroll through the available languages.
3. Press to select your desired language.
NOTE: For systems compliant with the EN 50131-1:2004 standard, you will need to
enter your Master Code to access and change the keypad language.
The following three options are accessed by entering [] [6] [Master code]. Use the
arrow (< >) keys to scroll to the appropriate message and press [] to select.
Brightness Control
The LCD keypad will allow you to select from 10 different backlighting levels. Use the arrow
keys (< >) to scroll to the desired backlighting level and press the [#] key to exit.
Press (*) For <>
Door Chime
Secure System