Programming Worksheets
31
Keypad Programming
[000] Keypad Enrollment (Section 2.5 Keypad Assignment on page 4)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
Slot Function Function Function Function Function
Key 1 Key 2 Key 3 Key 4 Key 5
LED Defaults 11 03 04 06 14 16
LCD Defaults 18 03 04 06 14 16
KEYPAD 1
I________I________I I________I I________I I________I I________I I________I
KEYPAD 2 I________I________I I________I I________I I________I I________I I________I
KEYPAD 3 I________I________I I________I I________I I________I I________I I________I
KEYPAD 4 I________I________I I________I I________I I________I I________I I________I
KEYPAD 5 I________I________I I________I I________I I________I I________I I________I
KEYPAD 6 I________I________I I________I I________I I________I I________I I________I
KEYPAD 7 I________I________I I________I I________I I________I I________I I________I
KEYPAD 8 I________I________I I________I I________I I________I I________I I________I
Basic Programming
Zone Definitions
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions
(Section 5.2 Zone Programming on page 15)
Default Default
01 I_______I_______I Zone 1 04 I_______I_______I Zone 5
03
I_______I_______I Zone 2 04 I_______I_______I Zone 6
03
I_______I_______I Zone 3 00 I_______I_______I Zone 7
03
I_______I_______I Zone 4 00 I_______I_______I Zone 8
00 Null Key 08 [*][1] Bypass Mode 16 [*][0] Quick Exit
01 For Future Use 09 [*][2] Trouble Display 17 [*][1] Reactivate Stay/Aways
02 For Future Use 10 [*][3] Alarm Memory 18 For future use
03 Stay Arm 11 [*][5] User Programming 19 For future use
04 Away Arm 12 [*][6] User Functions 20 For future use
05 [*][9] No-Entry Arm 13 Command Output #1 [*][7][1] 21 For future use
06 [*][4] Chime On / Off 14 Command Output #2 [*][7][2]
07 [*][6][——][4] System Test 15 For future use
00 Null Zone (Not Used) 10 24-hr Supervisory Buzzer 20 24-hr Freeze
01 Delay 1 11 24-hr Burglary 21 24-hr Latching Tamper
02 Delay 2 12 24-hr Holdup 22 Momentary Keyswitch Arm
03 Instant 13 24-hr Gas 23 Maintained Keyswitch Arm
04 Interior 14 24-hr Heating 24 GSM Answer
05 Interior, Stay/Away 15 24-hr Medical 25 Interior Delay
06 Delay, Stay/Away 16 24-hr Panic 31 Night Zone
07 Delayed 24-hr Fire (Hardwired) 17 24-hr Emergency 87 Delay 24-hr Fire (Wireless)
08 Standard 24-hr Fire (Hardwired) 18 24-hr Sprinkler 88 Standard 24-hr Fire (Wireless)
09 24-hr Supervisory 19 24-hr Water