32
[002] Zone 9-16 Definitions
(Section 5.2 “Zone Programming” on page 15)
Default Default
00
I_______I_______I Zone 9 00 I_______I_______I Zone 13
00
I_______I_______I Zone 10 00 I_______I_______I Zone 14
00
I_______I_______I Zone 11 00 I_______I_______I Zone 15
00
I_______I_______I Zone 12 00 I_______I_______I Zone 16
[003] Zone 17-24 Definitions
(Section 5.2 “Zone Programming” on page 15)
Default Default
00 I_______I_______I Zone 17 00 I_______I_______I Zone 21
00
I_______I_______I Zone 18 00 I_______I_______I Zone 22
00
I_______I_______I Zone 19 00 I_______I_______I Zone 23
00
I_______I_______I Zone 20 00 I_______I_______I Zone 24
[004] Zone 25-32 Definitions
(Section 5.2 “Zone Programming” on page 15)
Default Default
00 I_______I_______I Zone 25 00 I_______I_______I Zone 29
00
I_______I_______I Zone 26 00 I_______I_______I Zone 30
00
I_______I_______I Zone 27 00 I_______I_______I Zone 31
00
I_______I_______I Zone28 00 I_______I_______I Zone 32
[005] System Times
Default Valid entries: [001-255]
030
I_______I_______I_______I Entry Delay 1 (in seconds)(Section 5.19 “Entry/Exit Delay Options” on page 25)
045 I_______I_______I_______I Entry Delay 2 (in seconds)(Section 5.19 “Entry/Exit Delay Options” on page 25)
120 I_______I_______I_______I Exit Delay (in seconds)(Section 5.19 “Entry/Exit Delay Options” on page 25)
004 I_______I_______I_______I Bell Cut-off (in minutes)(Section 5.14 “Bell” on page 23)
[006] Installer’s Code (Section 4.1 “Installer’s Programming” on page 13)
Default
5555 I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes” on page 15)
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code (Section 5.1 “Programming Security Codes” on page 15)
Default
AAAA I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.12 “PGM Output Options” on page 21)
Programmable Output Options
01 Burglary and Fire Bell Output 14 Ground Start Pulse
02 For future use 15 Remote Operation (DLS-1 Support)
03 Sensor Reset 16 GSM1000 Support (PGM1 only)
04 For future use 17 Away Armed Status
05 System Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 ([*][7][1])
07 Keypad Buzzer Follow Mode 20 Command Output #2 ([*][7][2])
08 Courtesy Pulse 21 Command Output #3 ([*][7][3])
09 System Trouble Output (with Trouble options) 22 Command Output #4 ([*][7][4])
10 System Event [Strobe (with Event options)] 23 Silent 24-hr (PGM2 Only)
11 System Tamper (all sources: zones, kpd, modules) 24 Audible 24-hr (PGM2 Only)
12 TLM and Alarm 30 Status Alarm Memory
13 Kissoff Output
NOTE:Output types [03] and [20] cannot be used together on the same system.
Default Default
19 I_______I_______I PGM 1 10 I_______I_______I PGM 2 Program PGM Option Attributes in sections [141] & [142].