Chapter 1
1.0 Quick Reference
The PowerSeries Neo Alarm System uses shortcut keys to access options or features on all models of keypads. When using an
LCD keypad, the PowerSeries Neo Alarm System additionally uses a menu based navigation system. The scroll keys can be used
to [Scroll] through the list of options contained within the current menu. For more information on keypads see: 2 “Understanding
your Keypad”. Lookup detailed information on any of the listed actions using the accompanying Section number.
Note:Some features must be enabled by installer.
Note:Bypass Groups are not permitted in UL listed installations.
Note:[*] - If configured by installer.
Status
Lights
Function Keys
Function
Keys
Status
Lights
Emergency
Keys
Emergency
Keys
Ready - Indicates system normal. Must be on to arm system. All zones
must be secured or bypassed and the system disarmed for this light to
activate.
Stay
Arm
Fire Alarm
Armed- Indicates system is armed. If the Ready light and the Armed
light are both on, an Exit Delay is in progress.
Away
Arm
Medical
Alarm
Trouble - On indicates a system malfunction or tamper. Flashing indic-
ates that the keypad has a low battery condition. Follow the instructions
displayed or enter [*][2] to view trouble. Correcting the trouble turns
off the indicator.
Chime Panic Alarm
AC Power - Indicates AC Power is present. The AC Power light will
turn off when AC is absent.
Reset
Sensors
Quick
Exit
Action Press Section
Arming and Disarming
Away Arm
for 2 seconds + [Access Code*]
3.1.2
Stay Arm
for 2 seconds + [Access Code*]
3.2
Night Arm When armed in stay mode [*][1] + [Access
Code*]
3.3
Disarm [Access Code]
3.1
No-Entry Arming [*][9] + [Access Code*]
3.4
Quick Arm/Quick Exit [*][0]
3.5
Abort Arming Sequence [Access Code]
Bypassing - All bypass commands begin with [*][1] + [Access Code*]
Bypass Individual Zones [3 Digit Zone #]
3.7.1
Bypass All Open Zones [9][9][8]
3.7.1
Recall Last Bypass [9][9][9]
3.7.1
Clear Bypass [0][0][0] OR [Scroll] Bypass Options + [*]
+ [Scroll] Clear Bypasses + [*]
3.7.1
Program Bypass Group [3 digit zone #s] + [9][9][5] OR [3 digit
zone #s] + [Scroll] Bypass Options + [*] +
[Scroll] Prg Bypass Group + [*]
3.8
Load Bypass Group [9][9][1] OR [Scroll] Bypass Options + [*]
+ [Scroll] Bypass Group + [*]
3.8
Common Functions
Set Time and Date [*][6] [Master Code] + [0][1]
8.2
Turn Chime ON/OFF
[*][4] + [Access Code*] OR
10.1
Change Brightness
[*][6] [Master Code] + [1][2] +
8.8
Change Contrast
[*][6] [Master Code] + [1][3] +
8.8
- 4 -