Page #9 background imageLoading...
Page #9 background image
6
Night Arming
To fully arm the system when it has been armed in Stay Mode, press [][1] at any keypad, or press
the night arming function key if it has been configured by your installer. All interior zones will now
be armed except for devices programmed as Night Zones.
Night zones are only armed in Away mode. This permits limited movement within the premises
when the system is fully armed. Ensure that your installer has provided you with a list identifying
zones programmed as night zones.
When the interior zones have been activated (i.e., [][1]), you must enter your access code to disarm
the system to gain access to interior areas that have not been programmed as night zones.
Arming Without Entry Delay
If you wish to arm your system without the entry delay, enter [][9] then your access code. The
Armed light will flash as a reminder that the system is armed and has no entry delay. An entry
through any zone programmed as a delay zone will create an instant alarm.
Quick Arm
When the Quick Arm feature is enabled, the system may be armed by simply pressing [][0] instead
of your access code. Please note that pressing [][0] will only allow you to arm the system; to
disarm, you must enter a valid access code. Your installer will inform you if the Quick Arm feature
has been enabled on your system.
Auto Arming
Your system can be programmed to automatically arm itself according to a programmed schedule.
To program the auto arm time, enter [][6] followed by your master code. Press [3]. Enter the time
using the 24 Hr format (00:00 - 23:59).
To enable or disable the auto arm feature, enter [][6] followed by your master code. Press [2] to
either enable or disable the feature. The keypad will beep 3 times if the feature is ON and once if it
is OFF.
NOTE: The correct system time and date must be programmed in order for the auto arm feature
to function properly. Please see "Setting the System Date and Time” on page 14 for instructions.
Quick Exit
When the Quick Exit feature is enabled, pressing [][0] while the system is armed will provide a two
minute window for you to exit the premises. During this time, you may open and close the
designated Entry/Exit door only once. Once the door is closed, the panel will end the two minute
quick exit delay. If the door is opened again, if the door is not closed after two minutes, or if another
zone is opened, the panel will begin the entry delay. Your installer will inform you if the Quick Exit
feature has been enabled on your system.
Disarming the System
Disarming from an LED Keypad:
Enter the premises through a designated Exit/Entry door; entering by any other door will sound an
immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the
system should be disarmed. Go to the keypad and enter your access code. If an error is made
entering the code, enter your code again. As soon as the correct code is entered, the Armed light
will go out and the keypad will stop beeping.
The correct access code must be entered before the entry delay period expires. If a valid access code
is not entered during this time, the system will go into alarm. The entry time delay may be changed
by your installer.
If an alarm occurred while the system was armed, the Memory light and the zone light
corresponding to the zone that caused the alarm will flash for 30 seconds. After the 30-second
period, the Memory light and zone light will stop flashing and the panel will return to the Ready
state. Pressing the [#] key during the 30-second period will cancel the alarm memory display. To view
other alarms, press [][3].
If a trouble was detected when the panel is disarmed, the Trouble light will turn ON. (See "Viewing
Trouble Conditions” on page 14 to determine the source of the trouble.) Please note that troubles
will not display while the system is in the Alarm Memory Display mode.

Other manuals for DSC PowerSeries PC1404

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1404 and is the answer not in the manual?

DSC PowerSeries PC1404 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries PC1404
CategorySecurity System
LanguageEnglish

Related product manuals