PowerSeries - PC1616/PC1832/PC1864
14
Section [016] Fourth System Option Code
Section [017] Fifth System Option Code
Section [018] Sixth System Option Code
[8] ON: the system activates the bell output if a telephone line trouble is detected while the system is armed. OFF: the system activates
the keypad buzzer trouble tone.
Option Description
[1] ON: the system supervises the AC input and displays a trouble if a failure is detected. OFF: AC Input is not supervised.
[2] ON: the trouble light will flash when an AC trouble is detected. OFF: the trouble light turns on, does not flash.
[3] ON: the keypad blanks (no indicator lights) if a key is not pressed for 30 seconds. OFF: the keypad does not blank.
[4] ON: a valid user code must be entered to restore normal keypad operation after the blanking. OFF: pressing any key will return the
keypad to normal operation.
[5] ON: keypad backlighting enabled. OFF: keypad backlighting disabled.
[6] ON: the system temporarily enables the Keypad Blanking feature if an AC failure is detected (to preserve the back up battery).
OFF: the system will operate as normal.
[7] ON: the keypad turns ON the Bypass light if zones are bypassed while the system is armed. OFF: the Bypass light turns OFF when
the system is armed.
[8] ON: the system supervises keypad tampers. OFF: the system does not supervise keypad tampers.
Option Description
[1] ON: the system does NOT associate wireless keys to user codes. OFF: the system will assign user code 17 to wireless key #01, user
code 18 to wireless key #02 etc. If the wireless key is used to arm or disarm, the system will report the Opening or Closing for the
associated User Code.
[2] ON: the system logs an RF Jam trouble condition if the condition is present for 5 minutes. OFF: the system logs the trouble
condition after 30 seconds.
[3] ON: the keypads beep if an RF Jam trouble is detected. OFF: the trouble is not annunciated via the keypad buzzer.
[4] ON: the Double Hit feature will be enabled. Two violations from the same zone within the Cross Zone Timer will be considered a
valid Police Code or Cross Zone event. The system will report the event and log it to the event buffer.
OFF: two alarms from the same zone is not a valid Police Code or Cross Zone event.
[5] ON: the system logs and communicates a Late-To-Close event when it auto-arms at the programmed time (not if auto arming was
caused by the No-Activity Arming feature). OFF: the system does not transmit or log a Late-To-Close eve
nt.
[6] ON: enables the Daylight Savings automatic clock adjustment feature. OFF: the system does not automatically adjust the clock for
Daylight Savings.
[7] For Future Use
[8] ON: the system only squawks the bell output when the system is armed in the Away mode. OFF: the system squawks the siren
when the system is armed in any mode. (See Section [14]).
Option Description
[1] ON: the system only transmits a Test Transmission reporting code if no other event was transmitted to the central station during the
programmed time. OFF the system always transmits a Test Transmission reporting code as programmed.
[2]-[4] For Future Use