EasyManua.ls Logo

DSC PowerSeries PC1832

DSC PowerSeries PC1832
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerSeries - PC1616/PC1832/PC1864
20
Section [379] Periodic DLS Time of Day
Programs the time the system will auto-call DLS. Program 4 digits – [HH][MM] using military standard. For a DLS auto-call at 11:00 pm,
program data [23][00]). Valid entries are [00][00] to [23][59]. Programming [99][99] will select a random time, [FF][FF] will disable it.
Please refer to the PC 1616/1832/1864 Reference Manual for a complete description of Periodic DLS.
Section [380] First Communicator Option Code
Section [381] Second Communicator Option Code
Section [382] Third Communicator Option Code
Option Description
[1] ON: the system communicator is enabled. OFF: the communicator is disabled.
[2] ON: the system transmits alarm restorals if the zone is restored and the bell has timed out. OFF: the system transmits alarm restorals
immediately when the zone is restored.
[3] ON: the panel uses rotary (pulse) dialing. OFF: the panel uses touchtone (DTMF) dialing
[4] ON: the panel will switch from touchtone dialing to rotary dialing after the 4th failed attempt to communicate.
OFF: the panel will use DTMF dialing for all dialing attempts.
[5] ON: the system uses the Third Phone Number to back up the First Phone Number. OFF: the Third Phone Number is disabled.
[6] ON: the system alternates between the First Phone Number and Third Phone Number when attempting to report an event.
OFF: the panel will dial the First Phone Number for the programmed number of attempts, then switch to the Third Phone Number.
[7] For future Use
[8] ON: the Delinquency feature follows zone activity. OFF: the Delinquency feature follows arming.
Option Description
[1] ON: the keypad beeps 8 times after successfully transmitting the Opening After Alarm reporting event. OFF: the keypad does not beep.
[2] ON: the bell output squawks 8 times after successfully transmitting the Opening After Alarm reporting event. OFF: the bell output does
not activate.
[3] ON: the system uses programmed reporting codes when transmitting using the SIA format.
OFF: the system automatically generates all reporting codes transmitted.
[4] ON: the system beeps the keypad 8 times after successfully transmitting a Closing reporting event. OFF: the keypad does not beep.
[5] ON: the system requests a Listen in/Two-way session the next time it calls the 1st/3rd Phone Number when the PC59xx transmits a
request. OFF: the system ignores the request from the PC59xx.
This Option is used with PC59xx series modules.
[6] ON: the system requests a Listen in/Two-way session the next time it calls the 2nd Phone Number when the PC59xx transmits a request.
OFF: the system will ignore the request from the PC59xx.
This Option is used with PC59xx series modules.
[7] ON: the system uses Contact ID format programmed reporting codes when transmitting reporting codes.
OFF: the system automatically generates all reporting codes transmitted.
[8] ON: the system will follow ULC Communication Priority OFF: the system will follow standard communications priority.
Option Description
[1] ON: the system will use the digit [5] as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
OFF: the system will use the digit [4] as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
[2] ON: the system will transmit all alarms during Walk Test. OFF: the system will not report alarm events during Walk Test.
WWW.DIYALARMFORUM.COM