EasyManua.ls Logo

DSC PowerSeries PC1832

DSC PowerSeries PC1832
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Programming Worksheets
31
[013] First System Options
[014] Second System Options
[015] Third System Options
[016] Fourth System Options
Opt Def ON OFF
1
R
Normally Closed Loops
9
R
End-of-line Resistors
2
R
Double End-of-line Resistors
9
R
Single End-of-line Resistors
3
9
R
Panel shows all Troubles when armed
R
Panel shows only Fire Troubles when armed
4
R
Tampers/Faults do not show as open
9
R
Tampers/Faults show as open
5
9
R
Auto Arm Schedule in [*][6] and installers
R
Auto-arm Schedule in Installer Programming Only
6
9
R
Audible Exit Fault Enabled
R
Audible Exit Fault Disabled
7
9
R
Event Buffer Follows Swinger Shutdown
R
Event Buffer Logs Events past Shutdown
8
R
Temporal Three Fire Signal Enabled
9
R
Standard Pulsed Fire Signal
Opt Def ON OFF
1
R
Arm /Disarm Bell Squawk Enabled
9
R
Arm /Disarm Bell Squawk Disabled
2
R
Bell Squawk During Auto-arm
9
R
No Bell Squawk During Auto-arm
3
R
Bell Squawk On Exit Delay
9
R
No Bell Squawk On Exit Delay
4
R
Bell Squawk On Entry Delay
9
R
No Bell Squawk On Entry Delay
5
R
Bell Squawk On Trouble
9
R
No Bell Squawk On Trouble
6
9
R
Audible Exit with Urgency
R
Silent Exit Delay
7
R
Exit Delay Termination Enabled
9
R
Exit Delay Termination Disabled
8
R
Residential Fire Bell is Continuous
9
R
Residential Fire Bell is Cut-off
Opt Def ON OFF
1
9
R
Fire Key Enabled
R
Fire Key Disabled
2
R
Panic Key Audible (Bell / Beeps)
9
R
Panic Key Silent
3
R
Quick Exit Enabled (ON for SIA CP-01)
9
R
Quick Exit Disabled
4
9
R
Quick Arming Enabled (No Code Required)
R
Quick Arming Disabled (Code Required)
5
R
Code Required for Bypassing
9
R
NO Code Required for Bypassing
6
R
Master Code NOT Changeable (ON for SIA CP-01)
9
R
Master Code Changeable
7
9
R
TLM Enabled
R
TLM Disabled
8
R
TLM Audible (Bell) when Armed
9
R
TLM Trouble Beeps when Armed
Opt Def ON OFF
1
9
R
AC Trouble Displayed
R
AC Trouble NOT Displayed
2
R
Trouble Light Flashes if AC Fails
9
R
Trouble Light does NOT follow AC Status
3
R
Blank Keypad when Not Used
9
R
Keypad Blanking Disabled
4
R
Code required to remove Keypad Blanking
9
R
No Code Required
5
9
R
Keypad Backlighting is Enabled
R
Keypad Backlighting is Disabled
6
R
Power Save Mode Enabled
9
R
Power Save Mode Disabled
7
R
Bypass Status Displayed While Armed
9
R
Bypass Status NOT Displayed While Armed
8
R
Keypad Tampers Enabled
9
R
Keypad Tampers Disabled