5.2 Programming Worksheets
45
[381] Second Communicator Options
[382] Third Communicator Options
*This option must remain OFF for SIA CP-01 installations.
** A Call Waiting Cancel on a non-Call Waiting line will prevent successful connection to the central station.
[383] Fourth Communicator Options
[389] T-Link Fault Check Timer
Default: 003I_______I_______I_______IValid entries are 001-255 minutes
DLS Downloading
[401] Downloading Option Codes
Opt Def ON OFF
1
R
Open After Alarm Keypad Ringback Enabled
9 R
Open After Alarm Keypad Ringback Disabled
2
R
Open After Alarm Bell Ringback Enabled
9 R
Open After Alarm Bell Ringback Disabled
3
R
SIA Sends Programmed Reporting Codes
9 R
SIA Sends Automatic Reporting Codes
4
R
Closing Confirmation Enabled
9 R
Closing Confirmation Disabled
5
9 R
Talk/Listen on Phone Lines 1/3
R
No Talk/Listen on Phone Lines 1/3
6
9 R
Talk/Listen on Phone Line 2
R
No Talk/Listen on Phone Line 2
7
R
Contact ID Uses Programmed Reporting Codes
9 R
Contact ID Uses Automatic Reporting Codes
8
R
Communications Priority Enabled
9
R
Communications Priority Disabled
Opt Def ON OFF
1
R
Contact ID Partial Closing Identifier is “5”
9
R
Contact ID Partial Closing Identifier is “4”
2
R
Alarm Communications Enabled During Walk Test*
9
R
Alarm Communications Disabled During Walk Test
3
R
Communication Cancelled Message Enabled (ON for SIA CP-01)
9
R
Communication Cancelled Message Disabled
4
R
Call Waiting Cancel Enabled**
9
R
Call Waiting Cancel Disabled
5
R
T-Link Interface Enabled
9
R
T-Link Interface Disabled
6
R
AC Failure Transmission Delay is in Hours
9
R
AC Failure Transmission Delay is in Minutes
7
R
Number of Dialing Attempt for Residential Dial is 1
9
R
Residential Dial Follows Dialing Attempts Counter
8
R
For Future Use
9
R
Opt Def ON OFF
1
R
Account Code Follows Phone Number
9
R
Acount Code Follows Partition
2
R
For Future Use
9
R
Opt Def ON OFF
1
R
Answering Machine/Double Call enabled
9
R
Answering Machine/Double Call disable
2
R
User Can Enable DLS Window
9 R
User Cannot Enable DLS Window
3
R
Call Back Enabled
9
R
Call Back Disabled
4
R
User Initiated Call Up Enabled
9
R
User Initiated Call Up Disabled
5
R
Auto Event Buffer Upload Enabled
9
R
Auto Event Buffer Upload Disabled
6
R
300 Baud Call Up
9
R
110 Baud Call Up
7
R
For Future Use
9
R
8
R
For Future Use
9
R