EasyManuals Logo

DSC PowerSeries PC1832 User Manual

DSC PowerSeries PC1832
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
7
Bypassing Zones with a PK5500/RFK5500/RFK5564
Start with disarming the system.
1. Press []
to enter the function menu. The keypad will display “Press for < > Zone Bypass”.
2. Press [1] or [], then your [access code] (if required). The keypad will display “Zone Search < >
Zone Name”.
3. Enter the two-digit number of the zone(s) to be bypassed (01-64).
You can also use the [<][>] keys to find the zone to be bypassed, and then press [] to select the zone.
The keypad will display “Zone Search < > “Zone Name?”. “B” will appear on the display to show that
the zone is bypassed. If a zone is open (e.g., door with door contact is open), the keypad will display
“Zone Search < > “Zone Name” O”. If you bypass the open zone, a “B” will replace the “O”.
4. To unbypass a zone, enter the two-digit number of the zone(s) to be bypassed (01-64). You can
also use the [<][>] keys to find the zone, and then press [] to select the zone. The “B” will dis-
appear from the display to show that the zone is no longer bypassed.
5. To exit bypassing mode and return to the Ready state, press [#].
Bypassing Zones with a PK5508/PK5516/PK5501/RFK5508/RFK5516/RFK5501
1. Disarm the system.
2. Press [][1], then your [access code] (if required).
3. Enter the two-digit number of the zone(s) to be bypassed (01-64). On PK5508/PK5516/RFK5508/
RFK5516 keypads, the zone light will turn on to indicate that the zone is bypassed.
4. To unbypass a zone, enter the two-digit number of the zone (01-64). On PK5508/PK5516/
RFK5508/RFK5516 keypads, the zone light will turn off to indicate that the zone is not bypassed.
5. To exit bypassing mode and return to the Ready state, press [#].
Activating All Bypassed Zones
1. Press [][1], then your [access code] (if necessary).
2. Press [0][0]. To exit bypassing mode and return to the Ready state, press [#].
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press [][1], then your [access code] (if necessary).
2. Press [9][9].
3. To exit bypassing mode and return to the Ready state, press [#].
Bypass Groups
A Bypass Group is a selection of zones programmed into the system. If you bypass a group of zones
on a regular basis, you can program them into the Bypass Group, so that you do not have to bypass
each zone individually every time. One Bypass Group can be programmed on each partition.
To program a Bypass Group:
1. Press [][1], then your [access code] (if necessary).
2. Enter the two-digit numbers (01-64) of the zones to be included in the Bypass Group. On
PK5500/RFK5500/RFK5564 keypads, you can also use the [<][>]keys to find the zone to be
included in the bypass group, and then press [] to select the zone.
3. To save the selected zone into the group, press [9][5].
4. To exit bypassing mode and return to the Ready state, press [#].
To select a Bypass Group when arming the system:
1. Press [][1], then your [access code] (if necessary).
2. Press [9][1]. The next time the system is armed, the zones in this group will be bypassed.
3. To exit bypassing mode and return to the Ready state, press [#].
NOTE: Bypass Groups are only recalled if the system is armed/disarmed after programming
the bypass group.
NOTE: This feature is not to be used in UL listed installations.

Other manuals for DSC PowerSeries PC1832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1832 and is the answer not in the manual?

DSC PowerSeries PC1832 Specifications

General IconGeneral
Zones8 on-board, expandable to 32
User Codes48
Keypads SupportedUp to 8
Operating Voltage16.5VAC
Backup Battery12VDC, 7Ah
PGM Outputs2
Wireless Zones32 (requires wireless receiver)
Auxiliary Power Output500 mA @ 12 VDC
Bell Output700mA @ 12VDC (PTC protected)